![CamTron CMNC-200 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/camtron/cmnc-200/cmnc-200_operating-instructions-manual_3773143019.webp)
Cywatch HD Megapixel IP camera Operating Instructions (Ver. 1.0)
CamTron Industrial Inc.
18
IP Mode
Three IP modes are supported. Depending on the selected mode, further configuration items
come as follows.
IP Mode
Selection
Description
Local IP
Fixed IP address
Local Gateway
Gateway IP address
Fixed IP
Local Subnet
Subnet mask
DHCP
N/A
☞
Please ask an IP address information from ISP provider or network manager.
DNS
Set DNS server IP address.
Base Port
Network base port to be used for communication among systems. In case for the IP
cameras and remote systems to be connected together, the port number must be identically
set.
HTTP Port
HTTP port use for web-based connection
RTSP port
Audio and video streaming from server to client conforms to RFC standards.
Streaming and direction
Protocol
Remarks
Server -> Client
- Audio and video
- RTP(RFC1889) / RTSP(RFC2326)
- RTP over RTSP(TCP)
Video: H.264
Audio: G.711 u-law
Client -> Server
- Audio
- Non standard*
Additional remarks
-
Audio channel from client to server is not implemented yet, for standard way of delivering
stream in such direction is not defined. The scheme can be discussed with client
application developers and can be implemented easily if the scheme is determined.
-
RTSP over HTTP tunneling will be supported soon.
Multicast IP
The multicast IP address selection range is between 224.0.1.0 and 238.255.255.255. The
selection can be used only when media protocol is set to Multicast. The multicast address
must be the same for the system to be connected using multicast protocol.