Manual und Technical Details 

 

Programming Time Vout [ms] 

Model

 

0-15V

 

0-30V

 

0-50V

 

0-90V

 

0-130V

 

0-180V 

Rise Time 0-100%, 10/100% Last, [ms] typ. 

15/15 

15/15 

15/15 

15/15 

15/15 

15/15 

Slew Rate 90-10%, 10/100% Last, [ms] typ. 

36/3.6 

104/10.4 

49/4.9 

57/5.7 

53/5.3 

100/10 

Output Capacity, [mF] typ. 

10.36 

10.36 

1.85 

0.64 

0.28 

0.28 

Interface Latency 

15ms including signal latency for 0-Umax programming 

 

Analog Interface 

Pin 

Name 

Type 

Function 

Signal 

Remarks 

Ureg + 

Input 

Voltage Programming 

0-10Vdc/20mA & 0-20mA 
multi-functional interface 

500 

Ω

 working resistance with voltage 

programming 

Ureg - 

Input 

Sense + 

Input 

Sense Control 

none 

Compensation max. 2V per load line 

Sense - 

Input 

 

Input

 

External Shutdown Remote 
ON/OFF 

Open Collector or Switch 

Voltage drop <1V with typical 2.3mA 

Remote - 

Input

 

 

Programming Interface Ureg 

The standard programming of the HSEUREG Series is an analogue 
interface. The output voltage is linearly proportional to the adjusted analogue 
control signal. If the control signal 0V applies the power supply delivers 0V at 
the output. The power supply is already working from 0V output voltage and 
low load with high precision. 
 
The analogue inputs are non-floating. The mass is connected to the DC 
negative output. The burden of the interface is 500

Ω

. 0-10V programming 

requires 20mA current. The latency to full compensation of V/C on the 
interface from 0-100% is typically 15ms for all HSEUREG models. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 








E

F
I
L
T
E

 

C
O
N
T
R
O

 

C

1 = transient filter 
2 = rectifier 
3 = inrush limiter NTC 
4 = load capacitor 
5 = transformer 
6 = storage choke 

Содержание HSEUREG Series

Страница 1: ...N Rail Specification Voltage programming from 0V Multi interface 0 10V 0 20mA Sense Shutdown remote ON OFF N 1 parallel operation Natural convection Precise dynamic response on load change Designed fo...

Страница 2: ...atural convection The 1kW models use a forced air cooling system with a fan In selecting the fan as with all our power supplies in our opinion we use with the German manufacturer EBM Papst the highest...

Страница 3: ...protective electrical separation 60Vdc Analogue Interface see table protective electrical separation 60Vdc working impedance 500 Accuracy 1 5 Interface Latency Interface 15ms including signal latency...

Страница 4: ...functional interface 500 working resistance with voltage programming 2 Ureg Input 3 Sense Input Sense Control none Compensation max 2V per load line 4 Sense Input 5 Remote Input External Shutdown Remo...

Страница 5: ...allow proper operation Remote Sensing Schematics Although the HSEUREG sense block is simpler it applies to the shown schematics Please note that the HSEUREG has no AUX connection feature and that the...

Страница 6: ...sections of all power supplies to the busbar or to the star point are identical Allow proper connection for low contact resistance If you want to use the sensing function connect it also to the star p...

Страница 7: ...ein a failure or malfunction could result in injury or death Mechanics ST HD Baseplate Cooling Temperature Management The temperature management of the HSEUREG series provides a direct dissipation of...

Страница 8: ...free air space of 50mm top bottom and 10mm sidewalls is required and for active devices 15mm space from the sidewalls One can use the DIN Rail installation equipped standard with our patented 35mm DI...

Страница 9: ...accordance with EN 60999 a x b 5 4 x 5 1mm 5 3mm 2 8 x 2 4mm 2 5mm Pitch P 10 16mm 5 08mm Wire Stripping Length fine wired Nominal Cross Section Wire End Ferrule Stripping Length Wire End Ferrule Str...

Страница 10: ...olts or operation outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to per...

Отзывы: