Camtec Power Supplies GmbH – Gewerbestraße 30 – D-76327 Pfinztal – Germany
p.3/3 06.13C
Phone 0049(721)46596-0 - Fax 0049(721)46596-77 –
www.camtec-gmbh.com
-
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
A
B
118,5
VI-Characteristic and Over Boost Operation (temperature control)
The HPV04801-Models base on a classic forward resonant converter. The HPV series provides an ideal at right angel VI-chart and with no
fold back. In result the HPV power supply units excellently apply to complex loads, LED-applications and dc-drives. Intentional our engineers
avoided to design an excessive power boost that can be found in less exact working control circuits of some power supply units on the
market. The HPV design places reliance on extraordinary huge electrolytic capacity that saves immense power reserves. The main
advantage of such a design is that the HPV power supply unit delivers its energy always constantly and always controlled. Even in fault
operation the connected load will never be endangered.
The Temperature Control follows the VI-characteristic. The output power will decrease over the voltage; the current will be delivered
constantly. In case of dangerous overheating the HPV will be safety shut down. After heat dissipation the HPV restarts (soft start)
automatically (auto recovery mode).
Coating Option (Option C):
We offer the HPV-series with optional coating. It is to be used in e.g. dusty, dirty, high humidity, or in awaiting quick temperature
changes. Short circuit and corrosion at print board lines and at solder points can be prevented. The coat itself is a transparent acrylic
resin. It is procured with a robotics varnishing machine.
Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, IPC-CC-830B, UL listed as permanent coating FileNo.: E80315 , UL94V-0
Safety Instructions: Please read all warnings and advices carefully before installing or operating the power supply. Retain this operation manual
always ready to hand.The power supply must be installed by specialist staff only.
Installation:
1.)
The HPV is designed for systems fulfilling the safety norms of
dangerous voltages/energy and fire prevention
2.)
Installation is restricted to specialists only, make sure that the AC
wire system is free of voltage
3.)
Opening the HPV, making any modifications to it, dismounting any
screws from it, operating the HPV out of specification and/or using it
in appropriate area will unevitably result in loosing manufactureres
guarantee; we decline taking any responsibility for risk of demages
caused to someones health or to any installed system.
4.)
Attention: The HPV has an internal input fuse. It is necessary to wire
an automatic circuit braker to the line. We suggest to use a 16A-
type with B-characteristic. It is verboten to operate the HPV without
protective earth wired. It essential to install a line switch before the
HPV.
Warnings:
Disregard these warnings can cause fire, electic shock, serious
accident and death.
1.
Never operate the HPV without Protective Earth
Conductor
2.
Before connecting the HPV to the AC wire system
make all wires free of voltage and assure accidently
switch on
3.
Allow neat and professionel cabeling
4.
Never open nor try to repair the HPV by yourself.
Inside are dangerous voltages that can cause electric
shock hazard.
5.
Avoid metal pieces or other conductive material to fall
into the HPV
6.
Do not operate the HPV under damp or wet conditions
7.
It is verboten to operate the HPV under Ex conditions
or in Ex-Area
position for free air convection
Konvektion
Airflow
Airflow
114,5
B
All parameters base on 15 minutes run-in @ full load / 25°C / 230Vac 50/60Hz, as otherwise stated.