background image

 

 

   

CPS-EP2000(R2) MANUAL

                 

Camtec Power Supplies GmbH  -  Gewerbestrasse 30  -  DE-76327  Pfinztal / Germany   

P.11/19 (01/2018.01.1) 

Tel. +49 (721) 46596 - 0  Fax +49 (721) 46596 - 77    

www.camtec-gmbh.com

   -   

[email protected]

 

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death) 

 

Fan Fail Signal (FF) 

The power supply fans are continuously monitored. FF occurs when one or both fans have an error (lower 
speed due to bearing contamination, blockage, or failures). A failure message is sent: The status signal FF 
applies high. Output Open Collector I

MAX

=10mA, V

LOW

0,6V, V

MAX

=30V. 

 

C/V Chart and Operating Point 

The output voltage set Vout is set with the potentiometer at the rear oft he power 
supply.  
The current limit is fix. 
The system integrator must make sure that the nominal output power does not 
exceed below values to protect the unit from operating under overload conditions. 
(also see OT thermal SD) 
 
 
 

Model 

Value UA1 (V) 

Value IA1 (A) 

Value UA2 (V) 

Value IA2 (A) 

Pmax (IA1/IA2) 

CPS-EP2000.024 

30Vdc 

66,7A 

24Vdc 

84A 

2001/2016W

 

CPS-EP2000.036 

45Vdc 

44,4A 

36Vdc 

56A 

1998/2016W 

CPS-EP2000.048 

58Vdc 

34,5A 

48Vdc 

42A 

2001/2016W 

CPS-EP2000.072 

90Vdc 

22,2A 

72Vdc 

28A 

1998/2016W 

CPS-EP2000.110 

150Vdc 

13,3A 

110Vdc 

18,2A 

1995/2002W 

 

Inrush Current Limiter (electronic) 

The power supply unit has an electronic current limiter 
(230Vac=14,6A

rms

/20,7A

peak

).  

 
It is a precisely working circuit instead of a usual simple NTC 
solution. The accuracy is ±10%, regardless of the operating 
temperature and the duty cycles (interval 

10s). We recommend 

the smallest circuit breaker a characteristic B with 16A. 

  
 
 
 
 
 

 

Temperature Monitoring & Derating 

The maximum ambient temperature during operation is + 60°C. If the 
overtemperature protection is activated, the power supply but not the fan is 
switched off. 
 
The measuring point is 50mm outside the power supply at the front side 
(fan/blower input). The power supply unit starts automatically when it has 
cooled down. 

 
 
 
 
 

 
 
 
 
 
 

Содержание CPS-EP2000

Страница 1: ...positions PFC 0 99 Features 3D Heat Dissipation CSB Current Share Bus Inhibit for safe interlocking Remote Shutdown Sense mode Current Monitoring 0 5V Power Good Relay DC ok Precise dynamics on load...

Страница 2: ...ns call for the highest standards of safety and interference suppression The device was developed in accordance with the requirements of EN61010 1 EN61010 2 201 EN62368 1 and the EMC standards EN55032...

Страница 3: ...witching contacts Inhibit Mode Interlock The inhibit circuit reliably prevents unintentional starting of the power supply The control loop is internally locked Since this blocking is done progressivel...

Страница 4: ...l shutdown autorecovery 70 C outside measuring point distance 10mm Hold Up Time 30ms 230Vac mains buffering at full load Inrush Current 14 6Aeff 20 7Apeak 230Vac active electronic inrush protection no...

Страница 5: ...nnected No Function 3 DGND Digital Ground 4 NC NC Not Connected No Function 5 NC NC Not Connected No Function 6 NC NC Not Connected No Function 7 FF Output Signal Fan Failure Open Collector 8 NC NC No...

Страница 6: ...01 1 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherei...

Страница 7: ...ercon powercon 20 a nac3fca CON1 Push In 0 14 1 5mm AWG26 16 CON2 CON3 CON4 DC M8 200A 60 C 250Vac 20A Neutrik PowerCon 3x2 5 mm Neutrik NAC3FCA Interface pluggable Push Pull Connectors from Weidmuell...

Страница 8: ...rop over long load lines The compensation amounts to a maximum of 2V per load line Under certain circumstances it can be expected to apply more complicated external interference suppression If sense i...

Страница 9: ...the participating power supplies is important To prevent one of the power supplies going early into the current limitation and display error message An uneven load and thus premature aging of the part...

Страница 10: ...orced Isolation of max 400Vdc and a basic isolation of max 600Vdc working voltage DC OK Relay DC Power Good The signal DC OK has potential free relay contacts changeover The contacts of CON1 Pin2 and...

Страница 11: ...ues to protect the unit from operating under overload conditions also see OT thermal SD Model Value UA1 V Value IA1 A Value UA2 V Value IA2 A Pmax IA1 IA2 CPS EP2000 024 30Vdc 66 7A 24Vdc 84A 2001 201...

Страница 12: ...licable to EN62368 1 Due to the dielectric strength of the internal components used only the models with an output voltage of 48Vdc and later are approved for series operation Other power supplies are...

Страница 13: ...Germany P 13 19 01 2018 01 1 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as lif...

Страница 14: ...al Safety Factory Test Field Test Owner 48Vdc 2800Vdc Type and factory test are the manufacturer While repating damage can happen to the power supply unit For the field test owner follow the below ins...

Страница 15: ...esult in injury or death Mechanics Aluminium housing IP20 Cooling is achieved via front to rear fans To ensure adequate heat dissipation 50mm to the front and 150mm blockade free distance from the dev...

Страница 16: ...w camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in inju...

Страница 17: ...o custom design power supplies Steplessly hard mount of the CPS EP2000 3000 power supply modules in a 3D room In practice that means that one can mount the modules into every angle imaginable Our 3D H...

Страница 18: ...on Article Number CPS EP2000 024 R2 24Vdc model incl analogue interface 3041101002CA CPS EP2000 036 R2 36Vdc model incl analogue interface 3041101003CA CPS EP2000 048 R2 48Vdc model incl analogue inte...

Страница 19: ...olts or operation outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to per...

Отзывы: