C/V Current Voltage Behaviour
The CPS-EC series provides a perfect current voltage chart. It has no
foldback or other abnormalities. The output voltage can drop down to zero
volts when the power supply is overloaded. The unit delivers a stable and
constant current to the outputs. The device can be used either in the CV or
in the CC mode (automatic switch over). When the output voltage is set to
the maximum demanded value and the current limit reaches its desired
margin, the output voltage drops linear down to zero and the unit delivers
constant current. Similar is when the upper margin of the voltage allows the
current to be dropped by the power reduction behaviour of the CPS-EC
series. The C/V setting must meet the Pmax = 1000W!
Model
Value UA1 (V)
Value IA1 (A)
Value UA2 (V)
Value IA2 (A)
Pmax
CPS-EC1000.024
30
33,3
24
42,0
1008W
CPS-EC1000.036
45
22,2
36
28,0
1008W
CPS-EC1000.048
58
17,2
48
21,0
1008W
CPS-EC1000.060
75
13,3
60
16,7
1008W
CPS-EC1000.072
90
11,1
72
13,9
1008W
CPS-EC1000.110
137,5
7,3
110
9,1
1008W
CPS-EC1000.150
180
5,6
150
6,7
1008W
CPS-EC1000.220
264
3,8
220
4,5
1008W
CPS-EC1000.300
360
2,8
300
3,33
1008W
Inrush Current Limiter
The unit is featured with an electronic inrush current limiter (ex. 230Vac = 9,8Arms / 13,8Apeak). The built-in
circuit is a very precise limiter and no simple NTC thermistor solution. The circuit works with an accuracy of
±10%. The accuracy is independent from the ambient temperature and from the number of switch-on
sequences. The quickest recommended MCB is B-type 10A (230Vac) / 20A (115Vac). The smallest power
relay or a contactor in front of the CPS-EC480 must cope 13,8A peak current (note 18,4A nominal 115Vac).
The inrush duration is 400ms and the overall power up time of the unit is 500ms. See the below drawings for
technical information.
Overtemperature Thermal Shutdown, Over Voltage Protection & Derating
OT Over Temperature
The maximum ambient temperature is +70°C. If the
power Supply exceeds this value (over temperature protection) it completely
shuts down (metering point 10mm from outside device). The device restarts
automatically into operation when the temperature drops to a normal value.
OVP Over Voltage Protection
Exceeding the OVP results in a locked
shutdown mode. Resuming the failure causes automatic restart into normal
operation. For the values please read the Technical Table on page 2.