10
DISPOSAL
SERVICE AND WARRANTY
The product packaging consists of recyclable materials. Dispose of these in an environmentally
appropriate manner.
In accordance with EU directive 2002/96/EC, the appliance must be disposed of properly at the
end of its service life. This involves the recycling of valuable substances contained within the
appliance and reduces the impact on the environment. For more information, contact your local
disposal company or the store where you purchased the appliance.
• Press the button (12) and remove the dust container (11D), by pulling on the hand grip (11A), from the
appliance [fig. E1].
• Unlock the flap (13) for the motor protection filter by applying pressure to the catch spring and pivoting
out the flap in an upward direction [fig. E6].
• Remove the motor protection filter (14) from the holder [fig. E7].
• Rinse the motor protection filter (14) and dry it completely.
• Insert the cleaned or a new motor protection filter (14) into the holder once again.
• Turn the exhaust air screen (16) in an anticlockwise direction as far as it will go and then remove it [fig.
E8].
• Remove the HEPA filter (15) [fig. E9].
• Rinse the HEPA filter (15) and dry it completely.
• Insert the cleaned or a new HEPA filter (15) into the appliance once again.
• Put the exhaust air screen (16) back in place and lock it by turning it in a clockwise direction.
Cleaning and replacement of the HEPA filter (15)
If repairs are required or for purchasing replacement parts contact a customer service centre authorised by
CAMPOMATIC
Indicate the product type and identify the ordered parts based on Figure [F].
A manufacturer warranty is provided for the appliance. Details can be found on the enclosed warranty sheet.
GB
V1.1
Replacement: Replace the filter at least once a year. This period can vary according to how the vacuum
cleaner has been used.
Assembly
• First insert the flap (13) into the appliance, with the two catches at the top, pressing this in a downward
direction until it locks into place in the appliance.
• Then insert the dust container (11D) once again into the compartment for the dust collecting system (17).
Cleaning: Only use cold flowing water to clean the filter. Ensure that the filter is completely dry prior to
reassembly. Clean the filter at least once every six months or more frequently if fine dust has been vacuumed.
Replacement: Replace the filter at least once a year. This period can vary according to how the vacuum
cleaner has been used.
reassembly. Clean the filter at least once every six months or more frequently if fine dust has been vacuumed.