Campomatic AC19MS Скачать руководство пользователя страница 8

 7

OPERATING  INSTRUCTIONS

Airflow direction control

The SWING and AIR DIRECITON button will be disabled when 
the air conditioner is not in operation(including when the  TIMER 
ON is set).
Do not operate the air conditioner for long periods with the air 
flow direction set downward in cooling or dry mode. Otherwise, 
condensation may occur on the surface of the horizontal louver 
causing moisture to drop on to the floor or on furnishings.
Do not move the horizontal louver manually. Always use the 
SWING or AIR DIRECTION button. If you move this louver 
manually, it may malfunction during operation. If the louver 
malfunctions, stop the air conditioner once and restart it.
When the air conditioner is started immediately after it was 
stopped, the horizontal louver might not move for approximately 
10 seconds.
Open angle of the horizontal louver should not be set too small, 
as COOLING or HEATING performance may be impaired due
to too restricted air flow area.
Do not operate unit with horizontal louver in closed position.
When the air conditioner is connected to power (initial power), 
the horizontal louver may generate a sound for 10 seconds,
 this is a normal operation.

CAUTION

!

Lever

Range

Range

   Adjust the air flow direction properly otherwise, it 
   might cause discomfort or  cause uneven room 
   temperatures.
   Adjust the horizontal louver using the remote 
   controller.
   Adjust the vertical louver manually.

  

To set the vertical air flow(Up--Down) direction

   

Perform this function while the unit is in operation.

   Use the remote controller to adjust the air flow 
   direction. The horizontal louver can be moved at 

O

   a angle of 6  for each press or set to move up 
   and down automatically. Please refer to the   
      REMOTE CONTROLLER  ILLUSTRATION
   for details.

   

   

To set the horizontal air flow direction (left - right)

Adjust the vertical louver manually using the lever 
on the left or right side of the vertical louver arm 
(Depending on model). Take care not to catch 
fingers on the fan, horizontal louver or to damage 
vertical louvers. When the air conditioner is in 
operational and the horizontal louver is  in a specific 
position, move the lever at left (or right, depending
 on model) end of the air outlet to the desired position.

    

,,

,,

Содержание AC19MS

Страница 1: ...any helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service ...

Страница 2: ...cord is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only CAUTION SOCIABLE REMARK Sociable remark 2 SAFETY PRECAUTIONS Warning 3 Caution 4 OPERATING INSTRUCTIONS Parts names 5 Operating temperature 6 Manual operation 6 Airflow direction control 7 How the a...

Страница 3: ...east free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when hazardous s...

Страница 4: ...may cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It contains contaminants and could make you sick It may cause fire and electric shock It may cause electric shock or fire This could damage your health No installation may cause fire and elec...

Страница 5: ... cond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off and disconnect the power contact a qualified service technician It may cause failure of applia...

Страница 6: ...dicator This indicator illuminates when the air conditioner is in AUTO operation DEFROST Indicator For cooling heating model only This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation DIGITAL DISPLAY Displays the current setting temperature when the air conditioner is in operation OPERATION indicat...

Страница 7: ...peration use the remote controller directly CAUTION 1 3 2 Mode Cooling operation Heating operation Drying operation Temperature 1 If air conditioner is used outside of the above conditions certain safety protection features may come into operation and cause the unit to function abnormally 2 Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of ...

Страница 8: ...ver in closed position When the air conditioner is connected to power initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation CAUTION Lever Range Range Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven room temperatures Adjust the horizontal louver using the remote controller Adjust the vertical louver manually To ...

Страница 9: ...ed while dehumidifying by repeating turning on and off of the cooling operation or fan only The fan speed indicator will display AUTO and low speed will be used To achieve optimal performance please note the following Adjust the air flow direction correctly so that it is not directed on people Adjust the temperature to achieve the highest comfort level Do not adjust the unit to excessive temperatu...

Страница 10: ... maintenance Turn the system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle Cleaning the air filter A clogged air filter reduces the cooling efficiency of this unit Please clean the filter once every 2 weeks 1 Lift the indoor unit panel up to an angle until it stops with a cl...

Страница 11: ...itioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Caution Air freshening filter Air freshening filter 1 2 4 Remove the A included Plasma Dust Collector Silver Ion filter Bio filter Vitamin C filter 3M air purifier filter from its support frame The removing and installation...

Страница 12: ...a high relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air conditioner You may hear a low hissing sound when the compressor is running or has just stopped running This sound is the sound of the refrigerant flowing or coming to a stop You can also hear a low squ...

Страница 13: ...a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function optional Power failure during operation will stop the unit completely For the unit without Auto restart feature when the power restores the OPERATION indicator on the indoor unit starts flashing To restart the operation push the ON OFF button on the remote co...

Страница 14: ...Fuse may have blown Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperature correctly For detailed method please refer to Using remote control section Clean the air filter Close the doors or windows...

Страница 15: ...CS421 U 202000180057 20100706 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Отзывы: