Camplux JK-5320 Скачать руководство пользователя страница 4

www.camplux.com

1

3

.

1

2

Fig. 1

  DANGER

●  

Failure to comply with the precautions and

    instructions provided with these stoves can result 

    in death, serious bodily injury and property loss 

    or damage from hazards of fire, explosion, burn, 

    asphyxiation, and/or carbon monoxide poisoning.

●  

Only persons who can understand and follow the 

    instructions should use or service these stoves.

●  

If you need assistance or information such as an 

    instruction manual or labels, contact the store 

    where you bought the stove.

There are two burners on the stove.

Correspondently there are two venturies. On each 

venturie there are two holes acting as first air 

inlets. These venturies as well as the air inlets are 

protected by the housing. So normally these 

venturies and the air inlets are free from obstacles. 

Even though, you will have to check these 

venturies and air inlets and clean them before 

every time of using to avoid unexpected 

obstructing of air supply.

Technical 

Characteristics

Model No. : JK-5320

Item No. : SG-208-CM

Gas consumption: 7.38MJ/Hr x2

Max output: 7,000BTU/Hr x2

Injector: 0.013inch x2

Category: Pressure regulated propane

Fuel: 16.4 oz disposable propane cylinders

Regulator: KGZ-5430

  To Set Up

This appliance shall only be used with the regulator 

supplied with the appliance and must only be 

connected to 16.4 oz disposable propane cylinders. 

The LP-gas cylinders used with stoves must be 

constructed and marked in accordance with the 

specifications for LP-gas cylindres of the U.S. 

Department of Transportation or Transport Canada, 

CAN/CSA B339.

  Parts List

Item       Part No.                Description
1            KGZ-5430             Regulator Assembly

●  Remove components from carton. (Fig. 1)

1. Stove         2. Regulator

●  Close both burner valves firmly. (Fig. 2)

Fig. 2

  CAUTION

●  

Keep all connections and fittings clean. Inspect 

    propane cylinder and stove propane connections 

    for damage before attaching.

●  

During set up, check all connections and fittings 

    for leaks using soapy water. Bubbles indicate a 

    leak. Never use a flame.

SERVICE SAFETY

The injector or orifice is well protected by specially designed structure. 

Even though it should be cleaned once a year. If the injector hole is blocked and no 

gas provided from the injector under normal gas pressure, you can try to use a thin 

pin to clean it open or you’d better contact with the after-sale center for help.

Injector hole

Visit Us: Camplux.com

[email protected]

3330-A Marathon Ct Charleston, SC 29418

(844) 538-7475

Содержание JK-5320

Страница 1: ...ORTANT Read these instructions for use carefully Familiarize yourself with the appliance before connecting it to its gas container Keep these instructions for future reference Visit Us Camplux com sup...

Страница 2: ...to be installed in or on boats or recreational vehicles Do not obstructing the flow of combustion and ventilation air WARNING Not for home or recreational vehicle use We cannot foresee every use whic...

Страница 3: ...product is designed to produce extremely minute non hazardous amounts of CO if used and maintained in accordance with all warnings and instructions Do not block air flow into or out of the stove Carbo...

Страница 4: ...d propane Fuel 16 4 oz disposable propane cylinders Regulator KGZ 5430 To Set Up This appliance shall only be used with the regulator supplied with the appliance and must only be connected to 16 4 oz...

Страница 5: ...rted position Fig 7 Fig 7 To Light Propane can accumulate in low places If you smell gas leave the area immediately Always attach or detach propane source outdoors never while stove is lighted near fl...

Страница 6: ...y to close the gas supply Fig 10 Fig 10 Fig 11 To Clean Make sure stove is cool Move stove away from flame including pilot lights and other ignition sources Remove propane cylinder from regulator and...

Страница 7: ...amaged or does not operate properly 14 The appliance is to be operated on a horizontal surface 15 Gas containers shall be changed in a well ventilated location preferably outside away from people and...

Страница 8: ...Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 844 538 7475...

Отзывы: