background image

CMX-3G-4SDI Set Up Instructions

 

 

1.  Secure the units in a safe loca on, where they will not be subject to impact and where there is 

room around the unit so nothing will interfere with the 

fi

ber op c cabling causing it to bend sharply 

in a  ght radius in any way which can severely a

ect the signal transfer.  

2.  Carefully connect your source(s) to the transmi er input(s) and the receiver unit output(s) to your 

receiving device input(s) using the BNC connectors on the transmi er and on the receiver unit. 

3. CLEAN* 

the 

ST 

fi

ber op cal cable contacts that will be used for connec ng the Tx and Rx units and 

a ach the 

fi

ber cable to the ST connec ons and secure, as you would secure a bayonet BNC. While 

pressing lightly in on the connector, twist it in a clockwise direc on about 1/8 to 1/4 of a turn and 
then release. The connector should stay inserted and have backwards spring pressure holding the 
bayonet in place. 

4.  Connect the included power supplies to the transmi er & receiver units, and plug them both into 

an AC power source. 

 

* CLEAN: All 

fi

ber op cal cable contacts (the end that is inserted and makes contact to enable light 

wave transmission through the 

fi

ber) require cleaning each  me before inser ng into a device’s out

puts or inputs. Failure to clean the contacts can damage the unit’s op cs over  me and also render the 
cable and the device nonopera onal.  

Use cleaning kits designed speci

fi

cally for 

fi

ber op cs. Other cleaners may add contaminants not seen 

by the naked eye which could damage cables and/or equipment. 

Camplex CMX

3G

4SDI 

 

 

 

        

 

 

 

 

 

 

 

Page 5 

Содержание CMX-3G-4SDI

Страница 1: ...USER MANUAL CMX 3G 4SDI 4 Channel 3G SDI Multiplexer Over Singlemode Fiber Extender ...

Страница 2: ...Converts 4 3G SDI camera inputs to one singlemode fiber Saves space and set up me Extends transmission distance Immune to EMI Supports SMPTE 424M 3Gbps HD SDI transmission up to 6 miles Camplex CMX 3G 4SDI Page 2 Specifica ons Input Power 12VDC 1A Center Posi ve Power Adapter Input 110 240VAC 50 60Hz 0 45A Power Consump on 8W Signal Format SMPTE 424M SMPTE 292M SMPTE 259M Data Rate 270Mbit s 1 48G...

Страница 3: ...mode Fiber Op c Output 7 12VDC 1A DC Power Jack 8 Chassis Ground Screw LED Indicators Power LED When power is properly connected LED will be red When there is a problem LED will blink or not light SDI Input LED TX SDI LED will be green when the SDI input is connected to a valid SDI signal RX SDI LED will be green when the SDI output is transmi ng a valid SDI signal and the transmi er and receiver ...

Страница 4: ...emode Fiber Op c Output 7 12VDC 1A DC Power Jack 8 Chassis Ground Screw LED Indicators Power LED When power is properly connected LED will be red When there is a problem LED will blink or not light SDI Input LED TX SDI LED will be green when the SDI input is connected to a valid SDI signal RX SDI LED will be green when the SDI output is transmi ng a valid SDI signal and the transmi er and receiver...

Страница 5: ...re a bayonet BNC While pressing lightly in on the connector twist it in a clockwise direc on about 1 8 to 1 4 of a turn and then release The connector should stay inserted and have backwards spring pressure holding the bayonet in place 4 Connect the included power supplies to the transmi er receiver units and plug them both into an AC power source CLEAN All fiber op cal cable contacts the end that...

Страница 6: ... the unit from overhea ng 6 Before cleaning turn off the power and unplug the unit from all connec ons Use a damp cloth Do not use liquid or aerosol cleaners 7 Do not overload outlets and extension cords as this may result in a risk of fire or electric shock 8 Enclosure entry is dangerous Never push objects of any kind including liquids into this unit through openings as they may touch dangerous vo...

Отзывы: