10
TROUBLE SHOOTING
Cartridge would not install
n
o gas supply in (
) position
Smell gas in “
l
” position
Low flame
u
neven flame
n
o ignition/
faulty ignition
extinction in operation
Trouble shooting
ignition knob is not turn to “
l
” position
P
turn ignition knob completely to
“
l
” and reset cartridge.
Safety device activated
P
P
P
Refer to explanation for safety
device / StoPgaz™ flame guard.
ignition knob malfunction
P
P
P
P
Contact local agent to repair.
Clogged nozzle
P
P
P
Contact local agent to repair.
Cartridge incorrectly installed
P
P
P
P
fit cartridge guide into cartridge
slot.
Clogged burner holes
P
P
P
use a metal brush to clean it.
GB
Troubles
Causes
G - TROUBLESHOOTING
Warranty Period
Years
2