FIGURE 7-7. Anchor bolt height
NOTE:
To ensure proper anchoring of the anchor bolts in the concrete, it is recommended the
anchor bolts be secured in place prior to the concrete pour. Placing the anchor bolts
after the pour may result in voids and weak adhesion, allowing the anchor bolts to
move after the concrete has set. Loose-fitting anchor bolts will impact the integrity of a
freestanding tower system.
6. Fill the hole with concrete (
(p. 17)). Remove the masking tape from the anchor
bolt threads once the concrete has been leveled. Allow three to four days for the concrete
to cure.
UT20 and UT30 Universal Towers
16
Содержание UT20
Страница 1: ...Revision 03 2020 Copyright 1993 2020 Campbell Scientific Inc...
Страница 10: ...FIGURE 5 1 UT20 tower UT20 and UT30 Universal Towers 7...
Страница 38: ...FIGURE 7 28 Bracket selection UT20 and UT30 Universal Towers 35...
Страница 41: ...A B 14 7 Page 1 of 3 A A B B C C 1 2 3 0 1 2 3 3 inch reference...
Страница 42: ...C 43 2 cm 17 in A UTBASE Page 2 of 3 A A B B C C 1 2 3 0 1 2 3 3 inch reference...
Страница 43: ...C B UTBASE Page 3 of 3 A A B B C C 1 2 3 0 1 2 3 3 inch reference...