UT10 Weather Station
the outer edge of the plastic transducer housing see FIGURE 4-11. If this edge
is used, simply add 8mm to the measured distance.
FIGURE 4-11. Distance from Edge of Transducer Housing to Grill
4.12.3 Mounting Options
There are two standard mounting options available for the SR50A sensor.
The first is the SR50A Mounting Kit, part number 19517. This bracket is used
to mount the SR50A to a CM206 crossarm or a pipe with a 1 in to 1.75 in OD.
FIGURE 4-12 and FIGURE 4-13 show a couple of angles of the SR50A
mounted to a crossarm. A u-bolt attaches the bracket to the crossarm and two
screws attach the SR50A to the bracket.
Another mounting option shown in FIGURE 4-14 utilizes a mounting stem
(part number 19484) and a NU-RAIL. The mounting stem is sized to fit a 1 in
NU-RAIL (#1049). This mounting method was used for the SR50
(predecessor to the SR50A ) and the stem can be used to fit the SR50A into
existing SR50 mounts.
FIGURE 4-12. SR50A Mounted to a Crossarm via the 19517 Mounting
Kit