TB4, TB4MM, CS700, and CS700H Tipping Bucket Rain Gages
2
degradation. However, this jacket will support combustion in air. It is rated
as slow burning when tested according to U.L. 94 H.B. and will pass
FMVSS302. Local fire codes may preclude its use inside buildings.
•
While assembling the CS700H, ensure that the coiled cable and the
neoprene jacket do not interfere with the tipping bucket mechanism when
placing the funnel on the base.
3. Initial Inspection
•
Upon receipt of the tipping bucket rain gage, inspect the packaging and
contents for damage. File damage claims with the shipping company.
Immediately check package contents against the shipping documentation
). Contact Campbell Scientific about any
discrepancies.
•
The model number and cable length are printed on a label at the
connection end of the cable. Check this information against the shipping
documents to ensure the expected product and cable length are received.
3.1 Ships With
The rain gages ship with:
(1) Allen wrench from original manufacturer
CS700H-AC version also ships with:
(1) Power supply and mounting hardware (Quint Power made by Phoenix
Contact)
4. QuickStart
A video that describes data logger programming using Short Cut is available at:
www.campbellsci.com/videos/cr1000x-datalogger-getting-started-program-
Short Cut
is an easy way to program your data logger to measure the
rain gage and assign data logger wiring terminals.
Short Cut
is available as a
. It is included in installations of
LoggerNet
,
PC200W
,
PC400
, or
RTDAQ
.
The following procedure also describes programming with
Short Cut
.
1.
Open
Short Cut
and click
Create New Program
.
2.
Double-click the data logger model.