LED comes on when the regulator has shorted the solar panel. The LED can be 
used to check operation of the panel and as an indication of the state of charge of 
the battery. 

As an initial test of operation of the panel, connect the regulator as shown, but do 
not connect the battery; leave the battery lead from the regulator disconnected. 
When the panel is exposed to sunlight the LED on the regulator should flash on 
and off indicating the panel is giving out a voltage with the correct polarity. 

With the regulator connected to the battery and the panel exposed to sunlight the 
LED should start to flash on and off as the battery comes near to being fully 
charged. 

The regulator supplied consumes about 5 mA of power all the time. 

3.2  Connecting the SP5 or SP10 to the Rechargeable CR200X, 

CR3000 and CR6 Dataloggers and the CH200, PS200, CH150 
and PS150 series Power Supplies 

Solar panels can be connected directly to the charging circuits of the rechargeable 
CR200X, CR3000 and CR6 dataloggers, and the CH200, PS200, CH150 and 
PS150 series power supplies as indicated below.  

The red LED built into the appropriate charging circuit comes on when enough 
light falls on the panel. Please see the CH200/PS200 and CR6 manuals regarding 
their LED indicators. The CR200X does not have an LED. 

The  LED  only  indicates  that  a  voltage  is  being  generated  by  the 
panel;  it  does 

not 

necessarily  indicate  that  the  batteries  are  being 

adequately charged. 

3.2.1  Dataloggers with built in chargers: the CR200X, CR3000 and CR6 

Any of the smaller solar panels can be connected directly to the built in charging 
circuit of the dataloggers. See below if using the SP30 panel with these 
dataloggers. 

Connect the wires from the panel to the charging circuit connector on 

the right-

hand side

 of the rechargeable CR3000 base. 

Do not connect to the 12V Power 

Input plug on the top of the datalogger.

 Polarity of the leads to the connector is 

not critical. 

3.2.2  CH200, PS200, CH150 and PS150 series Chargers 

Connect the wires to the solar charging circuit connectors on the power supplies – 
observing the polarity. See below if using the SP30 with these power supplies. 

3.3  Using the SP30 with systems containing smaller lead acid 

batteries 

The SP30 can be used with smaller (7 Ah) lead-acid batteries in many 
circumstances – for example in less favourable climatic conditions, and in high 
latitude installations, where solar radiation can be low. It can also be used in some 
high current applications, but it should be noted that the reserve capacity of the 
internal battery may be a limiting factor. Current limits in the charger circuit will 

NOTE 

NOTE 

Содержание SP5

Страница 1: ...Solar Panels Issued 20 5 15 Copyright 2010 2015 Campbell Scientific Ltd CSL 60 USER GUIDE...

Страница 2: ......

Страница 3: ...er the repair is under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for rep...

Страница 4: ......

Страница 5: ...t for recycling Any batteries contained within the product or used during the products life should be removed from the product and also be sent to an appropriate recycling facility Campbell Scientific...

Страница 6: ......

Страница 7: ...ore beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit...

Страница 8: ......

Страница 9: ...cid batteries 7 3 4 Using solar panels with the CH150 and CH200 chargers 8 3 5 Using solar panels with Morningstar regulators 8 4 Optimum Battery Size 8 5 Precautions 10 6 Maintenance 10 Figures 1 Gen...

Страница 10: ......

Страница 11: ...consumes a significant amount of power e g an Eddy Covariance system the SP60 or SP100 panel is normally specified Under these conditions the battery capacity should also be increased to suit e g usi...

Страница 12: ...amp provided The panel should face due South North in the southern hemisphere and the angle of the panel should generally be adjusted according to the following considerations For best performance in...

Страница 13: ...y details of bracket for the SP5 and SP10 The SP30 and larger standard panels are supplied with a Solar Panel Multi Fit bracket Part number 006607 This is a substantial bracket that fits many differen...

Страница 14: ...Solar Panels 4 Figure 3a Assembly drawing for fitting the multi mount bracket to a larger panel Figure 3b Solar panel mounted on pole using the multi mount bracket...

Страница 15: ...will vary with the model and make of panel supplied Smaller panels such as the SOP5 are fitted with a flying lead that is moulded into the back of the panel Larger panels have junction boxes on the b...

Страница 16: ...e to be wired into cables connecting the panel to the battery The wires of the shunt regulators are clearly identified Connect the shunt regulator as shown in Figure 5 Solar Panel Solar Batt VE VE VE...

Страница 17: ...200 and CR6 manuals regarding their LED indicators The CR200X does not have an LED The LED only indicates that a voltage is being generated by the panel it does not necessarily indicate that the batte...

Страница 18: ...gulators Please refer to the instruction supplied with those regulators Please note that the quiescent consumption of the regulator may be quite high e g 8 10 mA Please note the fuse warning below 4 O...

Страница 19: ...t effective to opt for a much larger battery to cover several months in the winter than to buy a much larger panel to give positive charging at all times If a larger battery is to be used with an exis...

Страница 20: ...tly 2 It is important to match panel output to battery capacity and current drain Although an incorrect choice of components can lead to undercharging of the batteries in overcast conditions there is...

Страница 21: ......

Страница 22: ...entific Centro Caribe S A CSCC 300N Cementerio Edificio Breller Santo Domingo Heredia 40305 COSTA RICA www campbellsci cc info campbellsci cc Campbell Scientific Ltd CSL 80 Hathern Road Shepshed Lough...

Отзывы: