Campbell SMP10 Скачать руководство пользователя страница 5

PLEASE READ FIRST 

About this manual 

Please note that this manual was originally produced by Campbell Scientific Inc. primarily for the North 
American  market. Some spellings, weights and measures may reflect this origin. 

Some useful conversion factors: 

Area:

   1 in

2

 (square inch) = 645 mm

2

 

Length:    

1 in. (inch) = 25.4 mm 

1 ft (foot) = 304.8 mm 
1 yard = 0.914 m 
1 mile = 1.609 km 

Mass:

  

1 oz. (ounce) = 28.35 g 
1 lb (pound weight) = 0.454 kg 

Pressure:

 

1 psi (lb/in

2

) = 68.95 mb 

Volume:

 

1 UK pint = 568.3 ml 
1 UK gallon = 4.546 litres 
1 US gallon = 3.785 litres 

In addition, while most of the information in the manual is correct for all countries, certain information 
is specific to the North American market and so may not be applicable to European users.  

Differences include the U.S standard external power supply details where some information (for 
example the AC transformer input voltage) will not be applicable for British/European use. 

Please note, 

however, that when a power supply adapter is ordered it will be suitable for use in your country. 

Reference to some radio transmitters, digital cell phones and aerials may also not be applicable 
according to your locality. 

Some brackets, shields and enclosure options, including wiring, are not sold as standard items in the 
European market; in some cases alternatives are offered. Details of the alternatives will be covered in 
separate manuals. 

Part numbers prefixed with a “#” symbol are special order parts for use with non-EU variants or for 
special installations. Please quote the full part number with the # when ordering. 

Recycling information 

At the end of this product’s life it should not be put in commercial or domestic refuse but 
sent for recycling.  Any batteries contained within the product or used during the 
products life should be removed from the product and also be sent to an appropriate 
recycling facility. 

Campbell Scientific Ltd can advise on the recycling of the equipment and in some cases 
arrange collection and the correct disposal of it, although charges may apply for some 
items or territories.  

For further advice or support, please contact Campbell Scientific Ltd, or your local agent. 

Campbell Scientific Ltd, 80 Hathern Road, Shepshed, Loughborough, LE12 9GX, 

UK Tel: +44 (0) 1509 601141    Fax: +44 (0) 1509 

270924

Email: [email protected] 

www.campbellsci.co.uk 

Содержание SMP10

Страница 1: ...05 2019 Copyright 2019 Campbell Scientific ...

Страница 2: ......

Страница 3: ...s under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be given on request It is the policy of Campbell Scientific to protect the health of its employees and provide a safe working environment in support of this policy a Declaration of Hazardous Material and De...

Страница 4: ......

Страница 5: ...s digital cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European market in some cases alternatives are offered Details of the alternatives will be covered in separate manuals Part numbers prefixed with a symbol are special order parts for use with non EU variants or fo...

Страница 6: ......

Страница 7: ...e beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers Use only manufacturer recommended parts materials and tools Utility and Electrical You can be kil...

Страница 8: ......

Страница 9: ... 2 2 4 5 6 6 7 1 Introduction 2 Specifications 3 Siting 4 Mounting procedure 5 Wiring 6 Register map 7 RS 485 programming 8 Analogue programming 9 Example programs 10 Maintenance and troubleshooting 10 Table of Contents iv ...

Страница 10: ......

Страница 11: ...olar resource assessment and solar power performance applications Typically this pyranometer is oriented perpendicular to the Earth s surface to measure global horizontal irradiance GH Diffuse sky radiation can also be measured with the use of a shade mechanism 2 Specifications class A secondary standard Modbus over 2 wire RS 485 or 0 to 1 V ISO 9060 2018 classification Output Analogue output rang...

Страница 12: ...ion not exceeding 5 Diffuse solar radiation is less influenced by obstructions near the horizon The sensor should be mounted with the cable pointing towards the nearest magnetic pole For example in the northern hemisphere point the cable toward the North Pole 4 Mounting procedure Required tools l Diopter l Solar compass l 8 mm 5 16 inch open end wrench for U bolt nuts 1 On a level surface level th...

Страница 13: ...nting bracket The CM255 uses one U bolt nuts flat washers and lock washers to mount the bracket as shown in the following figure 5 For the CM255LS bracket use the two set screws to secure the bracket to the crossarm or pole as shown in the following figure For pyranometers mounted horizontally ensure the mounting bracket is horizontal in two dimensions For pyranometers mounted at an angle set the ...

Страница 14: ...nd Table 5 2 p 5 provides analogue wiring Table 5 1 RS 485 pin out wire colour function and data logger connection Wire colour Pin out Function Data logger connection1 MeteoPV connection Grey 5 RS485A C odd A Yellow 4 RS485B C even B White 7 Power in 12 V 12V 12V Black 8 Power ground G G Blue 2 Ground analogue ground analogue ground 1 Assumes the sensor directly connects to the data logger SMP10 P...

Страница 15: ...ground analogue ground 1 U channels are automatically configured by the measurement instruction 6 Register map RS 485 Register Map p 5 provides the register map for the most commonly used values A comprehensive register map is available in the Kipp and Zonen manual Table 6 1 RS 485 Register Map Starting register number Register count Data format Label Units Description 4 1 unsigned integer Status ...

Страница 16: ...tion has the following syntax SerialOpen ComPort Baud Format TXDelay BufferSize Mode The Format is typically set to logic 1 low even parity one stop bit 8 data bits The Mode parameter should configure the ComPort as RS 485 half duplex transparent The ModbusMaster instruction has the following syntax ModbusMaster Result ComPort Baud Addr Function Variable Start Length Tries TimeOut ModbusOption The...

Страница 17: ... Select the smallest input range that is greater than the maximum expected input voltage If electromagnetic radiation can be a problem use an fN1 of 50 or 60 Hz The multiplier converts the millivolt reading to engineering units Table 8 1 p 7 provides the calculations required for the various units The offset will normally be fixed at zero see Example programs p 7 Table 8 1 Multipliers required for...

Страница 18: ... no parity Modbus Address Set to 51 Public PTemp Units PTemp DegC Public Batt_volt Units Batt_volt VDC Dim Input_Reg 10 As Long Public SMP10_ResultCode Alias Input_Reg 1 Dev_Type Alias Input_Reg 2 Version Alias Input_Reg 3 Mode Alias Input_Reg 4 Dev_Flags Alias Input_Reg 5 R_S_Factor Alias Input_Reg 6 TC_SRad Alias Input_Reg 7 Raw_SRad Alias Input_Reg 8 Stan_Dev Alias Input_Reg 9 Body_Temp Alias I...

Страница 19: ...0 3 If SMP10_ResultCode 0 Then SMP10_NetRadiation Raw_SRad SMP10_NetRadTempCor TC_SRad SMP10_BodyTemp Body_Temp 0 1 Else SMP10_NetRadiation NAN SMP10_NetRadTempCor NAN SMP10_BodyTemp NAN EndIf CallTable Hourly NextScan EndProg CRBasic Example 2 CR1000X program using analogue voltage to measure the SMP10 CR1000X Series Datalogger Public PTemp Units PTemp DegC Public Batt_volt Units Batt_volt VDC Pu...

Страница 20: ...PV applications clean once per week bi monthly or monthly The SMP10 should be recalibrated following industry standard best practices such as ASTM G167 ISO 9846 ASTM E824 or ASTM G207 by an accredited lab The recommended recalibration interval is two years Contact Campbell Scientific for more information Unexpected results typically occur because of improper wiring or programming electromagnetic r...

Страница 21: ......

Страница 22: ...0033 0 1 56 45 15 20 Email info campbellsci fr Website www campbellsci fr Germany Location Bremen Germany Phone 49 0 421 460974 0 Email info campbellsci de Website www campbellsci de South Africa Location Stellenbosch South Africa Phone 27 21 8809960 Email sales campbellsci co za Website www campbellsci co za Southeast Asia Location Bangkok Thailand Phone 66 2 719 3399 Email thitipongc campbellsci...

Отзывы: