Use of the Siemens TC35T Digital Transceiver with Campbell Scientific Dataloggers
A-4
;and disable the PIN code transmission via P97, just in case it is still trying
15: Do (P86)
1: 11 Set Flag 1 High
16: End (P95)
17: End (P95)
*Table 2 Program
02: 0 Execution Interval (seconds)
*
End Program
-Input Locations-
1 Temp_C 1 0 0
2 Call_Fail 1 0 0
3 BadPINcnt 1 0 1
4 _________ 0 0 0
5 _________ 0 0 0
6 _________ 0 0 0
7 _________ 0 0 0
8 _________ 0 0 0
9 _________ 0 0 0
10 _________ 0 0 0
11 _________ 0 0 0
12 _________ 0 0 0
13 _________ 0 0 0
14 _________ 0 0 0
15 _________ 0 0 0
16 _________ 0 0 0
17 _________ 0 0 0
18 _________ 0 0 0
19 _________ 0 0 0
20 _________ 0 0 0
21 _________ 0 0 0
22 _________ 0 0 0
23 _________ 0 0 0
24 _________ 0 0 0
25 _________ 0 0 0
26 _________ 0 0 0
27 _________ 0 0 0
28 _________ 0 0 0
-Program Security-
0000
0000
0000
-Mode 4-
-Final Storage Area 2-
0
-CR10X ID-
0
-CR10X Power Up-
Other applications may require the PIN code to be sent prior to a callback call or
prior to sending an SMS message (see Technical Note 33 ‘Sending SMS Messages
using the TC35T’). For those applications which also use Instruction 97, the
AT+CPIN can either be sent first (as above) followed by a second call of P97 to