Campbell SC932A Скачать руководство пользователя страница 7

SC932A CS I/O to RS-232-DCE Interface 

2. Specifications

RS-232 9-Pin Male Connector Pin-out: 

Pin No.  I/O  Name  Description 

In 

DCD 

Data Carrier Detect (No Connection) 

In 

RXD 

Received Data 

Out  TXD 

Transmitted Data 

Out  DTR 

Data Terminal Ready (5 V Supply from CS I/O) 

GND 

Signal Ground 

In 

DSR 

Data Set Ready (No Connection) 

Out  RTS 

Request to Send – Modem Enable 

In 

CTS 

Clear to Send (No Connection) 

In 

Ring 

Rings Data Logger 

CS I/O 9-Pin Male Connector Pin-out: 

Pin No.  I/O 

Name 

Description 

in 

+5V

Regulated 5 Volt supply 

GND

Ground 

out 

RING

Ring signal to data logger 

out 

RXD

SC932A transmits on this line 

in 

ME

Modem Enable—must be high for transfer 

in 

SDE

Synchronous Device Enable—data blocked when high 

in 

TXD

SC932A receives on this line 

Содержание SC932A

Страница 1: ...SC932A CS I O to RS 232 DCE Interface Revision 12 2022 Copyright 1987 2022 Campbell Scientific CSL I D 483...

Страница 2: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Страница 3: ...cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European market in some...

Страница 4: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 5: ...ions 1 General Description 1 2 Specifications 2 3 Installation 3 4 RAD Modem Application 3 4 1 RAD Modem Two Way 4 4 2 RAD Modem Wiring and Grounding 4 4 3 Testing RAD Modem Communication 6 Figures 1...

Страница 6: ...the 5 V supply on pin 1 of the data logger s CS I O port The SC932A will use the 5 V supply to power the RS 232 modem if needed Two way interactive communication The SC932A is frequently used with a s...

Страница 7: ...Ground 6 In DSR Data Set Ready No Connection 7 Out RTS Request to Send Modem Enable 8 In CTS Clear to Send No Connection 9 In Ring Rings Data Logger CS I O 9 Pin Male Connector Pin out Pin No I O Nam...

Страница 8: ...oper transient protection should be installed to protect the computer and data logger in areas where damage due to lightning is possible If this is a RAD modem application see Section 4 2 RAD Modem Wi...

Страница 9: ...ollows 1 Set the DCE DTE switch on the back of the RAD modem connected to the SC932A to DCE For a RAD modem connected to a PC set the DCE DTE switch to DCE For a RAD modem connected to a serial printe...

Страница 10: ...stomer needs to transmit data across longer or smaller gauge wires or at higher speeds than can be done with the RAD modem powered by the SC932A RAD does sell a 9 volt power supply that will boost the...

Страница 11: ...em at the data logger end Twist together the XMT wire and RCV wire twist together the XMT wire and the RCV wire Repeat the process of step 1 by pressing a key on the computer keyboard If the key press...

Страница 12: ...nfo campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India...

Отзывы: