SC115 CS I/O 2G Flash Memory Drive with USB Interface
20
1. Click on the support software
Cancel
button to stop the connection
attempt.
2. Disconnect the SC115 from the computer for at least one minute.
3. After one minute, reconnect the SC115 to the computer and data logger.
4. Close the support software, then reopen it, then click on
Connect
.
14. Technical Reference
14.1 SDC Addressing
SDC addressing suitable for most applications is set at the factory.
The SC115 responds to two SDC addresses. SDC address 0 is used in data-
collection mode when data files are transferred from the data logger to the
SC115. This setting cannot be changed.
When plugged into a USB port, addresses SDC7, SDC8, SDC10, and SDC11
are available to support Communication Interface Mode on the CS I/O port.
This setting defaults to SDC7, but can be changed using
DevConfig
.
Before the SC115 can be configured through
DevConfig
, the
device driver must be installed.
DevConfig
is used to install the
device driver. Under
Device Type
, select
Peripheral | SC115
.
Click
Install USB Driver
and follow the prompts.
14.2 Formatting Memory
The SC115 is formatted at the factory and is ready to use out of the box.
Should the SC115 require formatting, such as if the memory becomes
corrupted, it can be formatted through data logger
File Control
(
LoggerNet
,
RTDAQ
,
PC400
,
PC200W
software), data logger keypad (
File
|
Format
|
USB
), or Windows
®
Explorer (
right click
|
Format
). When given an option
between formatting as FAT or FAT32, always choose FAT32.
Formatting will erase all files on the SC115.
14.3 Operating System
The SC115 is configured at the factory with an operating system. Unless
notified by Campbell Scientific, the operating system (OS) does not need to be
reloaded. Downloading a new OS to the SC115 should not affect files in
memory. It is good practice to retrieve all files from the SC115 before loading
a new OS.
NOTE
NOTE