background image

SC115 CS I/O 2G Flash Memory Drive with USB Interface 

20 

1. Click on the support software 

Cancel

 button to stop the connection

attempt.

2. Disconnect the SC115 from the computer for at least one minute.

3. After one minute, reconnect the SC115 to the computer and data logger.

4. Close the support software, then reopen it, then click on 

Connect

.

14. Technical Reference

14.1  SDC Addressing 

SDC addressing suitable for most applications is set at the factory. 

The SC115 responds to two SDC addresses. SDC address 0 is used in data-

collection mode when data files are transferred from the data logger to the 

SC115. This setting cannot be changed. 

When plugged into a USB port, addresses SDC7, SDC8, SDC10, and SDC11 

are available to support Communication Interface Mode on the CS I/O port. 

This setting defaults to SDC7, but can be changed using 

DevConfig

Before the SC115 can be configured through 

DevConfig

, the 

device driver must be installed. 

DevConfig

 is used to install the 

device driver.  Under 

Device Type

, select 

Peripheral | SC115

Click 

Install USB Driver

 and follow the prompts. 

14.2  Formatting Memory 

The SC115 is formatted at the factory and is ready to use out of the box. 

Should the SC115 require formatting, such as if the memory becomes 

corrupted, it can be formatted through data logger 

File Control

 (

LoggerNet

RTDAQ

PC400

PC200W

 software), data logger keypad (

File

 | 

Format

 | 

USB

), or Windows

®

 Explorer (

right click

 | 

Format

). When given an option 

between formatting as FAT or FAT32, always choose FAT32. 

Formatting will erase all files on the SC115. 

14.3  Operating System 

The SC115 is configured at the factory with an operating system. Unless 

notified by Campbell Scientific, the operating system (OS) does not need to be 

reloaded. Downloading a new OS to the SC115 should not affect files in 

memory. It is good practice to retrieve all files from the SC115 before loading 

a new OS.  

NOTE 

NOTE 

Содержание SC115

Страница 1: ...SC115 CS I O 2G Flash Memory Drive with USB Interface Revision 11 19 Copyright 2010 2019 Campbell Scientific CSL I D 873...

Страница 2: ......

Страница 3: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Страница 4: ......

Страница 5: ...digital cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European marke...

Страница 6: ......

Страница 7: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 8: ......

Страница 9: ...ettings Optional 4 8 Data Storage Modes 4 8 1 Data Collection Modes 4 8 1 1 Programming for the Data Collection Modes 5 8 1 2 Multiple Data Loggers 5 8 2 Resident Mode 5 8 2 1 Programming for the Resi...

Страница 10: ...nterface Function 16 12 Troubleshooting Memory Drive 17 12 1 Preventing Data Corruption 17 12 2 Skipped Scans 17 12 3 SC115 with Large Data Compliment 18 12 4 Data Collection Speed 18 12 4 1 External...

Страница 11: ...ta transfer See Section 12 1 Preventing Data Corruption p 17 to assess the risk in a particular application Always click Disconnect in the data logger support software prior to removing the SC115 when...

Страница 12: ...loggers DataTable Hourly 1 1 DataInterval 0 60 Min 0 TableFile USB Status SerialNumber _Filename 8 1 0 0 Min 0 0 Sample 1 PanelTempC FP2 Minimum 1 BattVolt FP2 0 False EndTable 5 Overview The SC115 is...

Страница 13: ...ive in Windows Explorer Data files on the SC115 can be copied or moved to other drives Files such as CRBasic program files or operating system OS files can be copied or moved from computer drives to t...

Страница 14: ...tion The parameters entered for the TableFile instruction depend on the data storage mode used refer to Section 8 Data Storage Modes p 4 Section 10 Data Logger Programming p 6 discusses in detail data...

Страница 15: ...bleFile instructions that enable data collection modes The first TableFile instruction enables the standard data collection mode The second TableFile instruction enables the enhanced data collection m...

Страница 16: ...the SC115 at midnight each day The second TableFile instruction sets the data logger to send bales of 24 records to the SC115 See Section 10 5 2 Resident Interval Mode Example p 14 for more detailed...

Страница 17: ...ts specific to SC115 applications For more detail consult CRBasic Editor Help TableFile is included in the DataTable EndTable declaration as shown in the programming examples in Section 10 5 Example P...

Страница 18: ...ry The data logger will not send additional data if the SC115 remains connected to the data logger number of data records value 0 0 N A compiler ignores The data logger sends the specified number of d...

Страница 19: ...y one uses the result as the name for a new file and writes the new data to the new file When multiple SC115s are used to collect data from multiple data loggers it is often desirable to set the inter...

Страница 20: ...rent number of files and overwrites the oldest file with new data Refer to the CRBasic Help system for detailed information on this parameter 10 1 4 NumRecs TimeIntoInterval Parameter Data Collection...

Страница 21: ...data to the SC115 whenever the number of new records matches the NumRecs TimeIntoInterval value 10 1 6 Units Parameter The Units parameter specifies the units used by the Interval parameter The compi...

Страница 22: ...file with TableFile after every 10 seconds every 100 records only 400 575 records may be written to the SC115 due to the program ending at the 600th scan prior to transferring all the records to the S...

Страница 23: ...ilename 8 1 0 0 Min 0 0 Sample 1 PanelTempC FP2 Minimum 1 BattVolt FP2 0 False EndTable BeginProg Scan 10 Sec 3 0 PanelTemp PanelTempC 250 Battery BattVolt CallTable Hourly NextScan EndProg 10 5 1 2 E...

Страница 24: ...olt FP2 0 False EndTable BeginProg Scan 10 Sec 3 0 PanelTemp PanelTempC 250 Battery BattVolt CallTable Hourly NextScan EndProg 10 5 3 Resident Record Number Mode Examples Plug In and Leave data baled...

Страница 25: ...lse EndTable BeginProg Scan 10 Sec 3 0 PanelTemp PanelTempC 250 Battery BattVolt CallTable Hourly NextScan EndProg 10 5 4 CardFlush Example In this example the SC115 remains at the data logger as resi...

Страница 26: ...te communications between the data logger and a computer The SDC address can be set to 7 8 10 or 11 see Section 7 2 SC115 Settings Optional p 4 Consider the following points when using the SC115 as a...

Страница 27: ...mRecs parameter in TableFile to match the Size parameter in the associated DataTable instruction Depending on the rate at which records are written this can cause data to be written to the SC115 at lo...

Страница 28: ...automatically transferred from the data table to the SC115 file How it works When CardOut is used in a DataTable EndTable declaration the file created on the external memory card becomes an extension...

Страница 29: ...t if large files from numerous data loggers need collection using the TOB1 format may save considerable time Consult the LoggerNet Instruction Manual for options available to convert TOB1 data files o...

Страница 30: ...onfig Before the SC115 can be configured through DevConfig the device driver must be installed DevConfig is used to install the device driver Under Device Type select Peripheral SC115 Click Install US...

Страница 31: ......

Страница 32: ...cennes France Phone 0033 0 1 56 45 15 20 Email info campbellsci fr Website www campbellsci fr Germany Location Bremen Germany Phone 49 0 421 460974 0 Email info campbellsci de Website www campbellsci...

Отзывы: