3.  SAT SCD/ARGOS Configuration

The SAT SCD/ARGOS PTT must be configured before you deploy it.  Two
numbers are used to track your data through the system.  The first number is
your Program ID, the second number is your SCD/Argos ID.  The PTT can use
up to 4 SCD numbers and up to 4 ARGOS ID numbers.  You must have your
SCD/Argos ID numbers before you can configure your PTT.  The SCD/Argos
ID number and transmission repetition rate is written to the SAT SCD/ARGOS
PTT during configuration.

3.1  SAT SCD/ARGOS Power Supply

During configuration, the PTT is powered through the SC532A.  For a power
supply the SC532A uses a 12 volt DC wall regulator/transformer or a direct
connection to a 12 volt battery.  The SC532A has an internal jumper.  The
jumper changes the operational mode of the SC532A.  In the “PROG” or
program mode, the SC532A will provide the interface between a computer and
the SAT SCD/ARGOS.  The SC532 mode is used for storage modules.  When
using the SC532A to configure the SAT SCD/ARGOS transmitter, configure
the jumper for “PROG”.

The SC532 will not work in place of the SC532A.

3.2  Pttcomm.exe

Included with each SAT SCD/ARGOS is a disk containing support software.
The information on the disk should be copied to a computer.  Load the disk in
the disk drive and execute “Setup.exe”. 

The computer must have a working RS 232 port.  Pttcomm.exe is a 32 bit
windows-based program.  Run Pttcomm.exe; use “File/Open” to open the
configuration file “SCD_Argos.cfg”. 

Edit your SCD/Argos ID number, or numbers if you are using more than one.
By setting an ID number to zero, the buffer is turned off.  All buffers not being
used should be set to zero.

Scroll down to  “SCD Transmission Rep Rate” and “Argos Transmission Rep
Rate”.  Enter the appropriate repetition rate for each field.  

The Argos channel number and SCD2 channel number can be set to a value
between 0 and 10.  Channel 5 is the center channel. 

In most cases, “Transmission On Time” and “Transmission Off Time” will not
need to be changed.  Transmission on time is the time the transmitter continues
to send bursts of data at the transmission repetition rates.  Transmission off time
is the amount of time the PTT is shut down after the transmission on time has
been completed.  Transmission on/off time starts when the PTT is powered up.
Transmission on and off time can be used to control the duty cycle of the
transmitter.  The transmission off time is not synchronized with the time of day.

NOTE

Содержание SAT SCD

Страница 1: ...SAT SCD ARGOS INSTRUCTION MANUAL REVISION 1 03 COPYRIGHT c 2000 2003 CAMPBELL SCIENTIFIC INC ...

Страница 2: ...This is a blank page ...

Страница 3: ...ty or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization To obtain a Returned Materials Authorization RMA contact CAMPBELL SCIENTIFIC INC phone 435 753 2342 After an applications engineer determines the nature of the problem an RMA number will be issued Please write...

Страница 4: ...This is a blank page ...

Страница 5: ...Data 4 2 3 3 P125 Result Codes 4 2 3 4 Using Result Codes In the Program 5 2 3 5 When to Execute P125 5 2 4 Program Example 5 3 SAT SCD ARGOS Configuration 7 3 1 SAT SCD ARGOS Power Supply 7 3 2 Pttcomm exe 7 3 2 1 Loading the Configuration to the PTT 8 4 Satellite Orbit Patterns 8 5 Antenna Placement 9 Figures 1 1 SAT SCD ARGOS 1 1 2 SAT SCD ARGOS with Enclosure 3 5 1 Complete Weather Station wit...

Страница 6: ...This is a blank page ...

Страница 7: ...r 16 Campbell Scientific data points Data must be decoded by the user SCD satellites follow an equatorial orbit with satellite passes approximately every two hours The SAT SCD ARGOS PTT supports up to four Argos ID numbers and four SCD2 ID numbers Message repeat intervals ID numbers and duty cycles can be changed with a simple to use computer based interface The transmitter connects directly to th...

Страница 8: ...l allows other SDC devices to be connected to the same serial port Power is supplied via the SC12 cable pin 1 and pin 8 Not all CR10X wiring panels supply 12 volts to pin 8 The CR10X wiring panel must include the text CR10X wiring panel The RF connector is an SMA female nominal output impedance is 50 ohms Transmit power is typically one watt The antenna is omnidirectional which is necessary becaus...

Страница 9: ...nt using 2 bytes you can send 16 data points in each data packet The Array ID is not sent If you are writing a time stamp to final storage don t forget to include the time stamp as additional data points The SAT SCD ARGOS can hold up to four data packets Each data packet is transmitted as a single message High resolution data points are four bytes but high resolution data are not supported by the ...

Страница 10: ... is used to set the active storage area By controlling where data is written and what storage area is active when P125 executes you can keep two separate data files This can be useful if you want to collect and store more data than you can transmit FS1 is the default storage area The datalogger always defaults to FS1 at the top of the program table If you plan to use FS2 you must allocate memory t...

Страница 11: ...replaced If P125 is executed when there is no new data in final storage P125 returns a result code of 1 Existing data is not removed from the PTT TABLE 2 1 P125 Result Codes Result Code Code Meaning 0 Normal response transmitter on line and data packet received 1 No new data in datalogger active final storage area 2 No response from the transmitter transmitter may be transmitting 3 Improper respon...

Страница 12: ...our Minute midnight 2400 5 Sample P70 1 13 Reps 2 3 Loc Start_1 If top of the hour transfer all new data to the SAT SCD ARGOS transmitter 6 If time is P92 1 0 Minutes Seconds into a 2 60 Interval same units as above 3 30 Then Do 7 SCD2 ARGOS P125 1 19 Return Code Loc R_Code 8 End P95 Check result of P125 if greater than 1 execute P125 again 9 If X F P89 1 19 X Loc R_Code 2 3 3 2 F 4 30 Then Do 10 ...

Страница 13: ...ed with each SAT SCD ARGOS is a disk containing support software The information on the disk should be copied to a computer Load the disk in the disk drive and execute Setup exe The computer must have a working RS 232 port Pttcomm exe is a 32 bit windows based program Run Pttcomm exe use File Open to open the configuration file SCD_Argos cfg Edit your SCD Argos ID number or numbers if you are usin...

Страница 14: ...PTT before the configuration program Pttcomm exe is ready On the PC load Pttcomm exe Click File preferences Set the correct communications port Also set the baud rate to 9600 Everything else should be left to the default values of UI Exit string QQQQQQG Platform WildCAT Prompt Wait In Seconds 70 Verify data as it is Written and Simple Mode not checked Click on file and open the configuration file ...

Страница 15: ...tellite coverage hourly data cannot be expected unless the PTT is located above 75 degrees latitude The number of successful data transmissions per satellite pass will increase with a decrease in the repetition rate More detailed information regarding Service Argos and satellite coverage is available from Service Argos On the Web see http www argosinc com The Service Argos North American office ca...

Страница 16: ...SAT SCD ARGOS 10 ...

Отзывы: