Appendix D. Setting Up RF401-to-CR206(X) Communications
D-6
RF401 Setup for Example 1 (see FIGURE
1. Since the RF401 will connect to a PC, select AutoSense or RS-232 Active
Interface.
2. Choose PakBus Aware for the Protocol.
3. Must use 9600 baud rate to communicate with a CR206(X). The baud rate
setting in the LoggerNet Setup screen must also be set to 9600.
4. Select Hop Sequence 0, which matches the CR206(X)'s hop sequence.
FIGURE D-5. DevConfig Deployment panel showing the RF401 setup
for Example 1.
5. Select Net Address 0, which matches the CR206(X)'s address.
6. The Radio Address is fixed at 0 when the Protocol is "PakBus Aware".
7. Select <2ma - 1 Sec Header for the Power Mode.
8. Select Retry Level Low.
9. Entry of a PakBus Address is disabled in DevConfig for the "PakBus
Aware" protocol.