background image

TABLE OF CONTENTS 

PDF viewers note:  These page numbers refer to the printed version of this document.  Use 
the Adobe Acrobat® bookmarks tab for links to specific sections. 

1.  INTRODUCTION

............................................................................................................................1 

2.  SPECIFICATIONS

.........................................................................................................................1 

3.  OPERATING INSTRUCTIONS

..................................................................................................2 

APPENDIX A.  RS232 D-CONNECTOR PIN FUNCTIONS

............................................... A-1 

 

 

 

Содержание MCR1

Страница 1: ...INSTRUCTION MANUAL MCR1 Memory Card Reader 5 93 C o p y r i g h t c 1 9 9 3 C a m p b e l l S c i e n t i f i c I n c ...

Страница 2: ...ther warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scientific Inc directl...

Страница 3: ...ese page numbers refer to the printed version of this document Use the Adobe Acrobat bookmarks tab for links to specific sections 1 INTRODUCTION 1 2 SPECIFICATIONS 1 3 OPERATING INSTRUCTIONS 2 APPENDIX A RS232 D CONNECTOR PIN FUNCTIONS A 1 ...

Страница 4: ...This is a blank page ...

Страница 5: ...e refer to the CSM1 manual for specifications of the memory cards supported Operating temperature 25 C to 50 C Power supply 1 6 20 VDC supplied by attached 110 120 AC adaptor Typical current from DC supply Inactive RTS low 16 mA maximum Active 30 mA average Interface type 25 pin D type sub miniature socket RS232C DCE interface Baud Rate 2 Supports all standard rates in the range of 300 to 38400 ba...

Страница 6: ...ations 4 POWERING WITH BATTERY The MCR1 is supplied with an AC adapter which allows the unit to be powered from a 110 120V 60Hz supply The output from this transformer is 8V DC nominal If required the adapter can be replaced by cutting the cable and connecting a battery in the range of 6 20 VDC e g a 12 V battery The conductor with the white stripe or raised ridge is the positive connection The ba...

Страница 7: ... MCR1 6 DSR data set ready to DTE held high at 5 V 7 Signal ground 8 DCD data carrier detect to DTE held high at 5 V directly connected to the internal 5V supply do not short to ground 1 Unlike the CSM1 SC532 only RTS is required for telecommunications mode the DTR line is not used 2 Only pins 2 3 4 and 7 need to be connected for use with the CSMCOM program For connection to a PC these pins should...

Страница 8: ......

Страница 9: ...This is a blank page ...

Страница 10: ... campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 rue de Te...

Отзывы: