Campbell LWS-L Скачать руководство пользователя страница 12

Campbell Scientific Companies 

 

Campbell Scientific, Inc. (CSI) 

815 West 1800 North 

Logan, Utah  84321 

UNITED STATES 

www.campbellsci.com • [email protected] 

 

Campbell Scientific Africa Pty. Ltd. (CSAf)

 

PO Box 2450 

Somerset West 7129 

SOUTH AFRICA 

www.csafrica.co.za • [email protected] 

 

Campbell Scientific Australia Pty. Ltd. (CSA)

 

PO Box 444 

Thuringowa Central 

QLD 4812 AUSTRALIA 

www.campbellsci.com.au • [email protected] 

 

Campbell Scientific do Brazil Ltda. (CSB)

 

Rua Luisa Crapsi Orsi, 15 Butantã 

CEP: 005543-000 São Paulo SP BRAZIL 

www.campbellsci.com.br • [email protected] 

 

Campbell Scientific Canada Corp. (CSC)

 

11564 - 149th Street NW 

Edmonton, Alberta T5M 1W7 

CANADA 

www.campbellsci.ca • [email protected] 

 

Campbell Scientific Centro Caribe S.A. (CSCC) 

300 N Cementerio, Edificio Breller 

Santo Domingo, Heredia 40305 

COSTA RICA 

www.campbellsci.cc • [email protected] 

 

Campbell Scientific Ltd. (CSL)

 

Campbell Park 

80 Hathern Road 

Shepshed, Loughborough LE12 9GX 

UNITED KINGDOM 

www.campbellsci.co.uk • [email protected] 

 

Campbell Scientific Ltd. (France) 

Miniparc du Verger - Bat. H 

1, rue de Terre Neuve - Les Ulis 

91967 COURTABOEUF CEDEX 

FRANCE 

www.campbellsci.fr • [email protected] 

 

Campbell Scientific Spain, S. L. 

Psg. Font 14, local 8 

08013 Barcelona 

SPAIN 

www.campbellsci.es • [email protected] 

 
 

Please visit www.campbellsci.com to obtain contact information for your local US or International representative. 

Содержание LWS-L

Страница 1: ...LWS L Dielectric Leaf Wetness Sensor Revision 3 09 C o p y r i g h t 2 0 0 8 2 0 0 9 C a m p b e l l S c i e n t i f i c I n c...

Страница 2: ...all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequen...

Страница 3: ...escription 1 2 Specifications 1 3 Installation 2 4 Wiring 3 5 Measurement 3 6 Interpreting Data 3 7 Operational Principles 4 7 1 Measurement 4 7 2 Leaf Mimicry 5 8 Example Programs 5 8 1 CR10X Datalog...

Страница 4: ...This is a blank page...

Страница 5: ...ace wetness by measuring the dielectric constant of the sensor s upper surface The sensor is able to detect the presence of miniscule amounts of water or ice Individual sensor calibration is not norma...

Страница 6: ...Leaf Wetness Sensor 3 Installation The LWS L is designed to be mounted on a small diameter rod Deployment in a plant canopy or on a weather station mast is typical Two holes in the sensor body are av...

Страница 7: ...of the excitation voltage The LWS L is intended only for applications wherein the datalogger provides short excitation leaving the probe quiescent most of the time Continuous excitation may cause the...

Страница 8: ...nts Collect data frequently enough to capture changes in surface wetness A sample frequency of 15 minutes or less is usually necessary to accurately capture leaf wetness duration NOTE 7 Operational Pr...

Страница 9: ...surface coating of the LWS L absorbs well in the near infra red region but the white color reflects most of the visible radiation Spectroradiometer measurements indicate that the overall radiation bal...

Страница 10: ...d changing the Boolean threshold Clean the sensing surface with a moist cloth periodically or when elevated dry output is detected LWS L sensors exposed to high levels of UV radiation develop a chalky...

Страница 11: ......

Страница 12: ...a Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller Santo Doming...

Отзывы: