LI200X Pyranometer
7.3 Wiring
A schematic diagram of the LI200X is shown in FIGURE 7-1.
Connections to Campbell Scientific dataloggers are given in TABLE 7-1.
When
Short Cut
software is used to create the datalogger program, the sensor
should be wired to the channels shown in the wiring diagram created by
Short
Cut
.
TABLE 7-1. Connections to Campbell Scientific Dataloggers
Color
Description
CR6, CR9000(X)
CR5000, CR3000
CR1000, CR800
CR850
Red
Signal
Differential High
Black
Signal Reference
Differential Low
White
Signal Ground
Clear
Shield
40.2 to 90.2
Ω
RED
BLACK
WHITE
CLEAR
H
L
AG OR GND
GND
FIGURE 7-1. LI200X Schematic
7.4 Programming
Short Cut
is the best source for up-to-date datalogger programming code.
Programming code is needed
•
when creating a program for a new datalogger installation
•
when adding sensors to an existing datalogger program
If your data acquisition requirements are simple, you can probably create and
maintain a datalogger program exclusively with
Short Cut
. If your data
acquisition needs are more complex, the files that
Short Cut
creates are a great
source for programming code to start a new program or add to an existing
custom program.
Short Cut
cannot edit programs after they are imported and edited
in
CRBasic Editor
.
NOTE