background image

 

Model HFP01

Soil Heat Flux Plate

Revision: 7/12

C o p y r i g h t   ©   2 0 0 2 - 2 0 1 2

C a m p b e l l   S c i e n t i f i c ,   I n c .

Содержание HFP01

Страница 1: ...Model HFP01 Soil Heat Flux Plate Revision 7 12 C o p y r i g h t 2 0 0 2 2 0 1 2 C a m p b e l l S c i e n t i f i c I n c...

Страница 2: ......

Страница 3: ...emoving reinstalling and shipping defective products to Campbell Campbell will return such products by surface carrier prepaid within the continental United States of America To all other locations Ca...

Страница 4: ...g container Campbell Scientific s shipping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Clea...

Страница 5: ...Wiring 5 6 3 Programming 5 6 4 Soil Heat Flux and Storage 7 7 Maintenance 8 8 References 8 Appendix A General Theory of Heat Flux Sensors A 1 A 1 General Theory A 1 A 2 Extended Theory A 2 Figures 6...

Страница 6: ......

Страница 7: ...hould be handled as a precision scientific instrument 3 Initial Inspection Upon receipt of the HFP01 inspect the packaging and contents for damage File damage claims with the shipping company The mode...

Страница 8: ...he sensor as the HFP01 The sensor s cable can terminate in Pigtails that connect directly to a Campbell Scientific datalogger option PT Connector that attaches to a prewired enclosure option PW Refer...

Страница 9: ...must be completely inserted into the soil face before the hole is backfilled FIGURE 6 1 Placement of heat flux plates 6 Installation 6 1 Placement in Soil The standard set of sensors for measuring soi...

Страница 10: ...t the side with the red label is facing the sky and the side with a blue label facing the soil NOTE In order for the HFP01 to make quality soil heat flux measurements the plate must be in full contact...

Страница 11: ...Shield Clear G 6 3 Programming To calculate the calibration multiplier divide 1000 by the nominal calibration sensitivity i e 1000 sensitivity The nominal calibration sensitivity is unique for each HF...

Страница 12: ...P01 1 1000 sensitivity 1000 67 1 Const HFP01_CAL_2 14 92 Unique multiplier for HFP01 2 1000 sensitivity 1000 67 0 Variables Energy balance sensors Public shf 2 Dim shf_cal 2 Soil heat flux plate calib...

Страница 13: ...n of CR23X Program using the Differential Measurement Instruction The instruction below does not store data in final storage P92 P77 and an output processing instruction are required to store the data...

Страница 14: ...lk density and mass basis soil water content can be found by sampling Klute 1986 The volumetric soil water content is measured by the CS616 water content reflectometer A value of 840 J kg 1 K 1 for th...

Страница 15: ...and the thermal conductivity of the sensor Using more thermocouples in series will enhance the output signal In Figure A 1 the joints of a copper constantan thermopile are alternatively placed on the...

Страница 16: ...r of magnitude of this error for strongly different thermal conductivity values between the sensor and its environment for example 0 6 for a typical sensor and 0 03 for an insulating wall is about 40...

Страница 17: ......

Страница 18: ...ntific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller...

Отзывы: