Model HC2S3 Temperature and Relative Humidity Probe
TABLE 7-6. Wiring for
Differential Measurement Examples
Color Description
CR1000
CR10(X)
Brown Temperature 1H
1H
Jumper to
Yellow
Temperature Signal
Reference
1L 1L
White Relative
Humidity 2H 2H
Yellow Signal
Reference 2L 2L
Gray Power
Ground G G
Clear Shield
G
Green Power 12V
12V
CR1000 program using differential measurements
'CR1000 program to measure HC2S3 with differential measurements
Public AirTC
Public RH
DataTable(Temp_RH,True,-1)
DataInterval(0,60,Min,0)
Average(1,AirTC,IEEE4,0)
Sample(1,RH,IEEE4)
EndTable
BeginProg
Scan(1,Sec,1,0)
'HC2S3 Temperature & Relative Humidity Sensor measurements AirTC and RH:
VoltDiff (AirTC,1,mV2500,1,True,0,_60Hz,0.1,-40)
VoltDiff (RH,1,mV2500,2,True,0,_60Hz,0.1,0)
If RH>100 And RH<103 Then RH=100
CallTable(Temp_RH)
NextScan
EndProg
CR10(X) program using differential measurement instructions
;{CR10X}
*Table 1 Program
01: 1.0000
Execution Interval (seconds)
;HC2S3 Temperature & Relative Humidity Sensor measurements AirTC and RH:
1: Volt (Diff) (P2)
1: 1
Reps
2: 25
2500 mV 60 Hz Rejection Range
3: 1
DIFF Channel
4: 3
Loc [ AirTC ]
5: 0.1
Multiplier
6: -40
Offset
18