Appendix D. SDI-12 Sensor Support
D-7
(p. D-7)
, are used with most Campbell Scientific
data loggers. Appendix
Changing an SDI-12 Address – CR200(X) Series
(p. D-7)
, lists the steps used for CR200(X)-series data loggers.
D.3.1 Changing an SDI-12 Address
The example below was done with a CR1000, but the steps are only slightly
different for CR1000X-series, CR300-series, CR6-series, CR800-series, and
CR3000 data loggers. For CR200(X)-series data loggers, see Appendix
Changing an SDI-12 Address – CR200(X) Series
1.
Connect an SDI-12 sensor to the CR1000.
2.
In
LoggerNet Connect
, under
Datalogger
, click
Terminal Emulator
. The
terminal emulator window opens.
3.
Under
Select Device
, located in the lower left side of the window, select
the
CR1000
station.
4.
Click
Open Terminal
.
5.
Select
All Caps Mode
.
6.
Press Enter until the data logger responds with the
CR1000>
prompt.
7.
Type
SDI12
and press Enter.
8.
At the
Select SDI12 Port
prompt, type the number corresponding to the
control port where the sensor is connected and press Enter. The response
Entering SDI12 Terminal
indicates that the sensor is ready to accept SDI-
12 commands.
9.
To query the sensor for its current SDI-12 address, type
?!
and press Enter.
The sensor responds with its SDI-12 address. If no characters are typed
within 60 seconds, the mode is exited. In that case, simply type
SDI12
again, press Enter, and type the correct control port number when
prompted.
10.
To change the SDI-12 address, type
aAb!
, where
a
is the current address
from the above step and
b
is the new address. Press Enter. The sensor
changes its address and responds with the new address.
11.
To exit SDI-12 transparent mode, click
Close Terminal
.
D.3.2 Changing an SDI-12 Address – CR200(X) Series
1.
Connect a single SDI-12 sensor to the CR200(X).
2.
In
LoggerNet Connect
, under
Datalogger
, click
Terminal Emulator
. The
terminal emulator window opens.
3.
Under
Select Device
, located in the lower left side of the window, select
the
CR200Series
station.
4.
Click
Open Terminal
.