CS-SRM Short Range Modem Package 

5. 

Close the unit by pressing the two halves of the cover together. Connect one 
modem directly to the RS232 port on the computer and connect the other to 
the SC932C interface. 

6. 

Referring to the SC932C manual, check that its internal jumpers are set in 
the correct position for use with the CS-SRM modem. 

7. 

This modem requires no specific set up in the latest version of PC400 or 
LoggerNet, as the software will be aware of its presence.  

3.1  Connection to a Remote Printer 

Please refer to the SC932C Manual for details of connection to a remote printer. 

3.2  Protection from Transients 

The RAD-SP spark-gaps provide protection both for the datalogger 
and RAD-SRM units from induced voltage transients in the 
interconnecting cable. Please be aware that the RAD-SRM linked to 
the computer can still be damaged by transients coming from the 
PC, and in such circumstances considerable damage is also often 
done to the PC itself. These transients can come from the AC power 
lines to the PC or its peripherals and/or connections to other remote 
peripherals (e.g. via network links) and are typically caused when 
lightning strikes overhead power lines. As the RAD-SP units and the 
datalogger protection devices act as low resistance clamps to 
ground, the PC may offer the path of least resistance to ground 
compared to other equipment. 

CAUTION 

To protect the PC and the RAD-SRM from this type of damage fit 
the power supply lines to the PC with good quality surge arrestors. 
These should also be fitted to any network or serial connections to 
other devices. Please contact your computer dealer for the supply of 
such devices. 

 

 

Содержание CS-SRM

Страница 1: ...CS SRM Short Range Modem Package User Guide Issued 26 6 07 Copyright 1995 2007 Campbell Scientific Ltd CSL 700...

Страница 2: ......

Страница 3: ...lieu of all other guarantees expressed or implied including those of suitability and fitness for a particular purpose Campbell Scientific is not liable for consequential damage Please inform us befor...

Страница 4: ......

Страница 5: ...rotection from Transients 4 4 Operating Distance 6 Figures 1 Typical installation of CS SRM in logger enclosure 2 2 Block Diagram of CS SRM Installation 3 3 Wiring and Installation of Surge Protectors...

Страница 6: ......

Страница 7: ...contact Campbell Scientific for advice R A D R A D S R M 5 A S R M 5 A U L R T H I S E Q U I P M E N T C O M P L I E S W I T H T H E R E Q U I R E M E N T S I N P A R T I S O F F C C R U L E S F O R...

Страница 8: ...mission range Up to 12km see Table 1 Line Interface 5 way four wires and ground via terminal block Power Requirements No external power required Takes less than 2 5mA quiescent 10 15mA active with SC9...

Страница 9: ...the receive pair to the terminals labelled RCV See Figure 2 note that the wires labelled A and B are one twisted pair of the cable and the wires labelled C and D are the other twisted pair A ground t...

Страница 10: ...ansients in the interconnecting cable Please be aware that the RAD SRM linked to the computer can still be damaged by transients coming from the PC and in such circumstances considerable damage is als...

Страница 11: ...User Guide DCE DTE Switch Figure 3 Wiring and Installation of Surge Protectors for a Typical CS SRM Setup 5...

Страница 12: ...5 5km 4 0km For distances up to 100m twin twisted pair cable such as that used for normal telephone installations will suffice For greater distances an overall screened twin twisted pair such as Beld...

Страница 13: ......

Страница 14: ...ll Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Lou...

Отзывы: