CRVW3 3-Channel Vibrating-Wire Datalogger
46
8.2.8.1 LED Operation
You can observe the LED behavior of the CRVW3 to assess its condition. The
LED lights can be observed from both the inside and the outside of the
enclosure.
FIGURE 8-17. LED Viewing Locations on the CRVW3
summarizes LED operation on the CRVW3.
TABLE 8-1. CRVW3 LED Behavior
RX/TX LED (left side)
Status LED (right side)
Solid Red
Radio Error
Solid Red
Measurement or Program Error
Solid Green
Measuring Sensor(s)
Solid Orange
Configuration of Radio, Busy,
No communications will
occur
Solid Orange
Configuration of Device
Settings or OS, Busy, No
communications will occur
Blinking Red
Radio Transmit (TX)
Blinking Red
No measurements possible with
only USB power
Also, for –RF451 option,
communication is not possible
with only USB power. (The
radio is not powered.)
Blinking Green
Radio Receive (RX)
Blinking Green
Awake (heartbeat)
Blinking Orange
No Carrier Detect (RF451
Radio Only)
Blinking Orange
Awake (heartbeat) – in Repeater
mode for –RF451 option
Off
No Radio Activity
Off
Device asleep or powered down
For CRVW3 devices without a communications option (no radio),
only the
Status
LED behavior shown above (right-side) is
applicable.
When the CRVW3 is powered up or has a change of settings applied, it
executes its startup sequence. During the final stage of the startup sequence,
you will see both LEDs in a solid orange state. Allow time for the startup
sequence to complete (up to 20 seconds) before attempting to connect to the
NOTE