15
7.4.1
Using an Additional CRS45X
One simple way to complete this correction is to deploy an additional CRS45X as
a reference sensor. For this method, in the Select Field Application window,
choose Barometer Pressure Reference (see Section
Error! Reference source not
found.
,
Configure CRS45X for Measurements
).
7.4.2
Using a Barometer
The barometric pressure data from a nearby Campbell Scientific weather station or
other Campbell Scientific monitoring platform also can be used to compensate for
barometric pressure. The
Data
tab is used to process and merge the data file from
the test sensor with the data file from the barometric reference sensor. The
procedure for doing this follows:
1. Press the browse button next to the
Collected Data File
field to browse to the
data files retrieved from the CRS45X.