NOTE:
The Power LED on the data logger indicates the program and power states. Because 
the data logger ships with a program set to run on power-up, the Power LED flashes 
three times every 10 seconds when powered over USB. When powered with a 12 V 
battery, it flashes once every 10 seconds. When no program is running, the LED is 
always on.

 7.  From the COM Port list, select the COM port used for your data logger. It will appear as 

CR300 series (COM number). 

 8.  USB connections do not typically require a COM Port Communication Delay; this type of 

delay allows time for hardware devices to "wake up" and negotiate a communications link. 
Accept the default value of 00 seconds and click Next.

 9.  You must match the PakBus address hardware settings of your data logger. A USB 

connection does not require a baud rate selection, keep the default.  The default PakBus 
address is 1.

 10.  Set an Extra Response Time if you have a difficult or marginal connection and you want the 

data logger support software to wait a certain amount of time before returning a 
communications failure error. Accept the default value of 00 seconds.

 11.  Set a Max Time On-Line to limit the amount of time the data logger remains connected. 

When the data logger is connected, communications with it are terminated when this time 
limit is exceeded. A value of 0 in this field indicates that there is no time limit for 
maintaining a connection to the data logger.

 12.  Leave the Neighbor PakBus Address as the default of 0. 

 13.  Click Next.

 14.  By default, the data logger does not use a security code or a PakBus encryption key. 

Therefore, the Security Code can be set to 0, and the PakBus Encryption Key can be left 
blank. If either setting has been changed, enter the new code or key.

 15.  Click Next.

 16.  Review the Setup Summary. If you need to make changes, click Previous to return to a 

previous window and change the settings.

 17.  Setup is now complete. The EZSetup Wizard allows you to Finish, or you may click Next to 

test communications, set the data logger clock, and send a program to the data logger. See 

Test the connection

 (p. 12) for more information.

2. USB communications

     

3

Содержание CR300 series

Страница 1: ...Revision 06 2023 Copyright 2023 Campbell Scientific Inc CR300 Series Compact Datalogger Getting Started Guide...

Страница 2: ...using Konect PakBus Router private dynamic IP 8 3 2 1 1 Configure data logger 8 3 2 1 2 Set up LoggerNet 10 3 2 1 3 Test the connection 12 3 3 Cellular TX RX LED Indicator 13 3 4 Signal strength and q...

Страница 3: ...the data logger l Collecting data from the data logger with a computer l Viewing real time and historical data with a computer In addition to your data logger the following items are used in this exer...

Страница 4: ...s click Setup select the View menu and ensure you are in the EZ Simplified view then click Add Datalogger l PC400 users click Add Datalogger 2 Click Next 3 Select CR300 Series from the list In the Dat...

Страница 5: ...a logger support software to wait a certain amount of time before returning a communications failure error Accept the default value of 00 seconds 11 Set a Max Time On Line to limit the amount of time...

Страница 6: ...dafone Telstra Other1 CELL205 4G LTE with automatic 3G fallback2 North America CELL210 4G LTE CAT 1 United States CELL215 4G LTE with automatic 3G and 2G fallback EMEA CELL220 4G LTE with automatic 3G...

Страница 7: ...to both Ethernet and a cellular modem IPRoute may be used to specify which interface to use for the outbound communications such as email FTP and HTTP A public static IP address can also be used This...

Страница 8: ...Gently slide the card into the slot until it stops and locks into place To eject the SIM card press it in slightly and release 3 Replace the SIM card cover Figure 3 1 SIM card installation 3 1 3 Konec...

Страница 9: ...be at the Welcome page 2 Click Devices and services on the command bar to the left and select Redeem PakBus Router Code Enter your complimentary Router Code found on the included card with your cellu...

Страница 10: ...logger 1 Connect the cellular antenna if it is not already connected When using a MIMO antenna with multiple cellular connections connect the primary cable to Cellular and the secondary to Diversity...

Страница 11: ...t User Name and Password if required by your cellular carrier usually outside of the United Sates 7 Optional If your cellular carrier requires user name and password authentication on the Settings Edi...

Страница 12: ...2 1 2 Set up LoggerNet The LoggerNet Network Map is configured from the LoggerNet Setup screen NOTE Setup has two options EZ simplified and Standard Click on the View menu at the top of the Setup scr...

Страница 13: ...ernet IP Address field in the format DNS Port with a colon separating DNS and Port For example axanar konectgds com pppp where pppp is the port number 5 Leave the default settings for the PakBusPort P...

Страница 14: ...ntered during data logger setup also enter it here Click Apply to save the changes 3 2 1 3 Test the connection Use the Connect screen to test the connection Click on the appropriate station and click...

Страница 15: ...o establish a connection with the provider periodic retries will occur l Solid Cellular modem is powering up and attempting to establish a connection with a provider l Quick Flashing approximately 1 s...

Страница 16: ...ted as RSSl Received Signal Strength Indicator For 4G it is RSRP Reference Signal Received Power Signal strength units are dBm 70 is a stronger signal than 100 Table 3 1 Signal strength Strength estim...

Страница 17: ...Table 3 2 Signal quality Quality estimate ECIO 3G dBm RSRQ 4G dBm Excellent 0 to 6 9 Good 7 to 10 9 to 12 Fair to poor 11 to 20 13 or less 3 Cellular communications option 15...

Страница 18: ...your data logger support software Use Short Cut software to generate a program for your data logger Short Cut is included with your data logger support software This section guides you through program...

Страница 19: ...ndow to learn more about any field or option For the example program accept the default options l 1 Type T TC sensor l Temp_C as the Temperature label and set the units to Deg C l PTemp_C as the Refer...

Страница 20: ...nstructions in Sending a program to the data logger p 20 Click No do not send the program to the data logger TIP It is good practice to always retrieve data from the data logger before sending a progr...

Страница 21: ...NOTE Once a Short Cut generated program has been edited with CRBasic Editor it can no longer be modified with Short Cut 4 Creating a Short Cut data logger program 19...

Страница 22: ...ideo 1 Connect the data logger to your computer l LoggerNet users select Main and Connect on the LoggerNet toolbar select the data logger from the Stations list then Connect l PC400 users select the d...

Страница 23: ...ick OK then click Station Status select the Table Fill Times tab Ensure that the times shown are expected for your application Click OK After sending a program it is a good idea to monitor the Public...

Страница 24: ...ta tables It also only updates when viewed l User defined data tables update at the schedule set within the program For information on collecting your data see Collecting data p 23 Use these instructi...

Страница 25: ...y be done manually or automatically through scheduled collections set in LoggerNet Setup Use these instruction or follow the Collect Data Tutorial 6 2 1 Collecting data using LoggerNet 1 From the Logg...

Страница 26: ...n 6 After the data is collected the Data Collection Results window displays the tables collected and where they are stored on the computer 7 Select a data file then View File to view the data See View...

Страница 27: ...nfo campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India...

Отзывы: