3

TABLE 3.  Temperature, Resistance, and

Datalogger Output

Temperature

Resistance

Output

°

C

OHMS

°

C

-40.00

4067212

-39.18

-38.00

3543286

-37.55

-36.00

3092416

-35.83

-34.00

2703671

-34.02

-32.00

2367900

-32.13

-30.00

2077394

-30.18

-28.00

1825568

-28.19

-26.00

1606911

-26.15

-24.00

1416745

-24.11

-22.00

1251079

-22.05

-20.00

1106485

-20.00

-18.00

980100

-17.97

-16.00

869458

-15.95

-14.00

772463

-13.96

-12.00

687276

-11.97

-10.00

612366

-10.00

-8.00

546376

-8.02

-6.00

488178

 -6.05

-4.00

436773

-4.06

-2.00

391294

-2.07

0.00

351017

-0.06

2.00

315288

1.96

4.00

283558

3.99

6.00

255337

6.02

8.00

230210

8.04

10.00

207807

10.06

12.00

187803

12.07

14.00

169924

14.06

16.00

153923

16.05

18.00

139588

18.02

20.00

126729

19.99

22.00

115179

21.97

24.00

104796

23.95

26.00

95449

25.94

28.00

87026

27.93

30.00

79428

29.95

32.00

72567

31.97

34.00

66365

33.99

36.00

60752

36.02

38.00

55668

38.05

40.00

51058

40.07

42.00

46873

42.07

44.00

43071

44.05

46.00

39613

46.00

48.00

36465

47.91

50.00

33598

49.77

52.00

30983

51.59

54.00

28595

53.35

56.00

26413

55.05

58.00

24419

56.70

60.00

22593

58.28

TABLE 4.  Polynomial Coefficients

Coefficient

Value

C0

-53.4601

C1

90.807

C2

-83.257

C3

52.283

C4

-16.723

C5

2.211

6.  ELECTRICALLY NOISY

ENVIRONMENTS

AC power lines can be the source of electrical
noise.  If the datalogger is in an electronically
noisy environment, the CR10TCR temperature
measurement should be measured with the AC
half bridge (Instruction 5) with the 60 Hz rejection
integration option on the CR10 (see Section 13
of the datalogger manual for more information
on noise).  Instruction 11's fast integration will
not reject 60 Hz noise.

Example 2.  Sample CR10 Instructions Using

AC Half Bridge

01:

P5

AC Half Bridge

01:

1

Rep

02:

22

7.5 mV 60 Hz rejection Range

03:

1

IN Chan

04:

3

Excite all reps w/EXchan 1

05: 2000

mV Excitation

06:

15*

Loc [:Ref_Temp]

07:

800

Mult

08:

0

Offset

02:

P55

Polynomial

01:

1

Rep

02:

1*

X Loc Air Temp

03:

15*

F(X) Loc [:Ref_Temp]

04:

-53.46

C0

05:

90.807

C1

06:

-83.257

C2

07:

52.283

C3

08:

-16.723

C4

09:

2.211

C5

*

Proper entries will vary with program and
input location assignments.

Содержание CR10TCR

Страница 1: ...CR10TCR THERMOCOUPLE REFERENCE REVISION 12 96 COPYRIGHT c 1995 1996 CAMPBELL SCIENTIFIC INC ...

Страница 2: ...This is a blank page ...

Страница 3: ...antability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization To obtain a Returned Materials Authorization RMA contact CAMPBELL SCIENTIFIC INC phone 435 753 2342 After an applications engineer determines the nature of the problem an RMA number will be issued Plea...

Страница 4: ...This is a blank page ...

Страница 5: ... combination of the thermistor s interchangeability specification the precision of the bridge resistors and the polynomial error In a worst case all errors add to an accuracy of 0 4 C over the range of 24 to 48 C and 0 9 C over the range of 38 C to 53 C The major error component is the interchangeability specification of the thermistor tabulated in Table 1 For the range of 0 to 50 C the interchang...

Страница 6: ...AG H L AG G G E1 E2 1 2 3 1 2 3 4 5 6 G 5V 5V P1 P2 C8 C7 C6 C5 C4 C3 C2 C1 CONTROL 12V SWITCHED CR10TCR LT 343403 FIGURE 4 CR10TCR Installed on the CR10 Wiring Panel 4 PROGRAMMING Instruction 11 is used to measure the CR10TCR Instruction 11 provides AC excitation makes a single ended voltage measurement and calculates temperature with a fifth order polynomial A multiplier of 1 0 and an offset of ...

Страница 7: ...46 00 39613 46 00 48 00 36465 47 91 50 00 33598 49 77 52 00 30983 51 59 54 00 28595 53 35 56 00 26413 55 05 58 00 24419 56 70 60 00 22593 58 28 TABLE 4 Polynomial Coefficients Coefficient Value C0 53 4601 C1 90 807 C2 83 257 C3 52 283 C4 16 723 C5 2 211 6 ELECTRICALLY NOISY ENVIRONMENTS AC power lines can be the source of electrical noise If the datalogger is in an electronically noisy environment...

Страница 8: ...CR10TCR THERMOCOUPLE REFERENCE 4 This is a blank page ...

Отзывы: