Keyword
Information and Location
CompileResults
Contains error messages generated at compilation or during runtime.
Updated after compile. Also appended to at run time for run time errors
such as variable out of bounds.
l
String data type
l
Read only
ErrorCalib
Number of erroneous calibration values measured. Erroneous values are
discarded. Updated at startup.
l
Numeric data type
l
Read only
FullMemReset
Enter 98765 to start a full-memory reset.
l
Numeric data type
LastSystemScan
Reports the time of the of the last auto (background) calibration, which
runs in a hidden slow-sequence type scan. See
, and
.
l
Numeric data type
l
Read only
LithiumBattery
Voltage of the internal lithium battery. Updated at CR1000X power up. For
battery information, see
l
Numeric data type
l
Read only
Low12VCount
Counts the number of times the primary CR1000X supply voltage drops
below ≈9.0 Vdc. Updates with each Status table update. Range = 0 to 99.
Reset by entering 0. Incremented prior to scan (slow or fast) with
measurements if the internal hardware signal is asserted.
l
Numeric data type
l
Read only
MaxBuffDepth
Maximum number of buffers the CR1000X will use to process lagged
measurements.
l
Numeric data type
9. Tips and troubleshooting
131
Содержание CR1000X
Страница 1: ...Revision 02 21 2019 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...Appendix A Glossary 176 Appendix B Index 214 Table of Contents viii ...
Страница 20: ...l Smart sensors o SDI 12 o RS 232 o Modbus o DNP3 o TCP IP o RS 485 1 Data acquisition system components 4 ...
Страница 192: ......
Страница 237: ...wiring panel 5 Appendix B Index 220 ...