Appendix B. Status, Settings, and Data Table Information (Status/Settings/DTI)
SkippedScan
(p. 628),
MaxProcTime
(p. 620).
ProgErrors
Keyboard:
Status Table
≈ line 25
CRBasic:
variable = status.keyword
Number of compile or runtime errors for the running
program.
read-only
LONG
counts
0
≥ 0
ProgName
Station Status:
Current Program
Keyboard:
Status Table
≈ line 10
CRBasic:
variable = status.keyword
Name of current (running) program
read only
STRING
n/a
n/a
ProgSignature
Station Status:
Program Signature
Keyboard:
Status Table
≈ line 13
CRBasic:
variable = status.keyword
Signature of the text of the running program file
(includes comments). Does not change with
operating-system changes. See
RunSignature
(p.
The CRBasic pre-compiler gets this signature
with command line parameter
–s
. The output will
add a line of the following form:
“Progname.CReX – Compiled in
PipelineMode.
ProgSignature = XXXX.”
read only
LONG
n/a
n/a
Table 181.
Status/Settings/DTI: R
Keyword
Alias,
Access,
Description
Read/Write,
DataType,
Units
Default
Value
Normal
Range
RecNum
Keyboard:
Status Table
,
DTI Table
≈ header left
CRBasic:
variable = status.keyword
Record number increments for successive status-
table data records.
read only
LONG
n/a
0 to 2
32
RevBoard
Keyboard:
Status Table
≈ line 8
CRBasic:
variable = status.keyword
Electronics board revision in the form
xxx.yyy
,
where
xxx
= hardware revision number;
yyy
= clock
chip software revision. Stored in flash memory.
read only
STRING
n/a
n/a
RouteFilters
Settings Editor:
Route Filters
Keyboard:
Settings (General)
≈ line 12
CRBasic:
variable = settings.keyword
;
SetSettings()
Restricts routing or processing of some PakBus
message types. See section
Route Filters
(p. 405)
read/write
STRING
(0, 0, 0, 0)
0 to 351
characters
RS232Handshaking
Settings Editor:
RS232 Hardware Handshaking
Buffer Size
Keyboard:
Settings (General)
≈ line 21
CRBasic:
variable = settings.keyword
;
SetSettings()
If non-zero, hardware handshaking is active on the
RS-232
port. This setting specifies the maximum
packet size sent between checking for CTS.
read/write
LONG
0
0
to
65535
626
Содержание CR1000
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 36: ......
Страница 38: ......
Страница 40: ......
Страница 60: ...Section 4 System Quickstart Figure 16 PC200W View Line Graph 60 ...
Страница 96: ......
Страница 98: ...98 ...
Страница 302: ......
Страница 350: ...Section 8 Operation Figure 91 Pulse Sensor Output Signal Types Figure 92 Switch Closure Pulse Sensor 350 ...
Страница 453: ...Section 8 Operation Figure 115 Using the Keyboard Display 453 ...
Страница 454: ...Section 8 Operation 8 8 1 Data Display Figure 116 Displaying Data with the Keyboard Display 454 ...
Страница 456: ...Section 8 Operation Figure 118 Real Time Custom 456 ...
Страница 457: ...Section 8 Operation 8 8 1 3 Final Memory Tables Figure 119 Final Memory Tables 457 ...
Страница 458: ...Section 8 Operation 8 8 2 Run Stop Program Figure 120 Run Stop Program 458 ...
Страница 460: ...Section 8 Operation Figure 122 File Edit 460 ...
Страница 461: ...Section 8 Operation 8 8 4 PCCard Memory Card Display Figure 123 PCCard CF Card Display 461 ...
Страница 478: ......
Страница 506: ......
Страница 536: ......
Страница 636: ......
Страница 642: ......
Страница 644: ......
Страница 676: ......
Страница 677: ......