7. Troubleshooting COM320 Voice Systems
Following are some possible reasons for your COM320 system not working or
not working properly.
7.1 No Communications
Voice Mode — No voice announcements when you call the station
•
The COM320 is connected to a digital rather than an analog phone line.
•
The COM320 configuration was changed from its default factory settings
Updating and Configuring the COM320
(p. B-1)
Data Mode — Can’t connect to the station with
LoggerNet
software.
•
No commas and/or “9” added to the dial string in
LoggerNet
to
temporarily put the COM320 into
data
mode.
•
The “9” is being dialed before the COM320 ‘picks up’ and voices the
announcement (not enough commas).
•
No phone number in the
LoggerNet
dial string.
•
COM320 is connected to a digital rather than an analog phone line.
•
LoggerNet Setup
configured for the wrong PC modem.
•
LoggerNet
configured for a baud rate the station cannot handle (try 9600).
•
COM320 configuration was changed from its default factory settings
Updating and Configuring the COM320
(p. B-1)