COM310 Voice Communications Modem
FIGURE 3. COM310 / CR1000 Using Surge Protection Device
(where there’s no available Standard RJ11 Connection)
6.2 Powering the COM310 Modem
Newer Campbell Scientific dataloggers provide 12 VDC on CS I/O connector
pin 8 for powering peripherals such as the COM310. The alternative, if you
have a dataloggers/wiring panel lacking 12 VDC on pin 8, is to wire the green
connector on the side of the COM310 to the data12 VDC and power
ground terminals (refer to Figure 4). The COM310 comes with a mating green
power connector for this purpose. The following Campbell Scientific
dataloggers lack 12 VDC power on CS I/O pin 8.
TABLE 1. Dataloggers/Wiring Panels
Lacking 12 VDC on CS I/O Port Pin 8
CR10(X) w/ silver wiring panel
CR10(X) w/ black CR10 wiring panel (P/N 8032)
CR500
⎯
serial number 1764 or lower