PS150/CH150 12 V Charging Regulators
11
AC/DC Transformer with Interchangeable Blades: Campbell Scientific
Model No. 29796-US
Input Voltage:
100 – 240 Vac
Input Frequency:
47 – 63 Hz
Output Voltage:
24 Vdc
Output Current (max):
1.67 A
Protection:
Unit will auto-recover upon removal of fault.
UL Approval:
UL60950-1 2
nd
Edition
Unit has interchangeable blades. Unit ships with US/Canada plug installed.
For international orders select option 29798 –IP for international blades.
International blade selection contains blades for Australia/New Zealand, UK,
Europe/South America, Korea, Argentina, China, & India/South Africa.
AC/DC DIN Rail Mount Power Adapter: Campbell Scientific Model No.
28370
Input Voltage:
85 – 240 Vac or 90 – 350 Vdc
Input Frequency:
45 – 65 Hz
Output Voltage:
24 Vdc
Output Current:
3.8A (–25 to 70 °C)
Protection:
3.15A internal slow-blow fuse
Approval:
ETL Listed for US and Canada
Both of the recommended chargers have dc voltage output which
can be used on either the
CHARGE/CHARGE
or
SOLAR/G
terminal blocks. Maximum input charging current on the
CHARGE/CHARGE
terminal blocks is limited to 1.1 Adc.
Maximum input charging current on the
SOLAR/G
terminal
blocks is limited to 3.6 Adc.
CHARGE/CHARGE
terminal blocks have no polarity. Power wires from the
charging source can be connected in any fashion. The PS150/CH150 will only
float charge a battery with power connected to the
CHARGE/CHARGE
terminal blocks which is fine when using an AC/DC charging source.
SOLAR/G
terminal blocks do have a polarity that must be followed when
wiring up either of the AC/DC devices. Positive wire goes to the terminal block
marked
SOLAR
. Negative wire goes to the terminal block marked
G
. Higher
power throughput makes this an attractive option. It will float charge a battery
but it will also try to quick charge as well depending on the needs of the
battery.
NOTE