manualshive.com logo in svg
background image

PS100 and CH100 Power Supply and Charging Regulators 

 

Power Out (+12 terminals) 

 

Voltage: 

Unregulated 12 V from Battery 

Current Limited w / 3 A Thermal Fuse:  > 3 A @ < 20

°

 

3 A @ 20

°

 

2.1A @ 50

°

 

1.8 A @ 60

°

Battery Packs  

Operating Temperature Range: 

-40 to +60ºC 

Capacity:  
PS100 

7 Amp hours 

BP12 

12 Amp hours 

BP24 

24 Amp hours 

These batteries are designed to be float charged.  
Permanent damage occurs and battery life is 
shortened if the battery is allowed to discharge below 
10.5 volts.

 

WARNING 

AC Transformer: CSI Model No. 9591 

Input Voltage: 

120 VAC 

Output Voltage: 

18 VAC RMS 

Output Current (max): 

1.2 Amps RMS 

Protection (automatic reset):  

85

°

C thermal reset breaker  

UL Approval: 

UL-1950 

AC Transformer: CSI Model No. 14014 

Input Voltage: 

90 - 264 VAC; 47 - 63 Hz 

Output Voltage: 

18 VDC 

Output Current (max): 

1.3 Amps 

UL Approved, File No.: 

E137895 

PS100 

Physical Specifications: 

10.5 cm tall, 19 cm long, 
7 cm wide 

 

3.  Wiring 

An internal or external battery is connected to the charger by means of the INT 
(Internal) or EXT (External) connectors, as shown in Figure 1.  An “external 
battery” cable is available for the charger.  This cable connects another battery 
with the charger to provide power if the main battery is removed.  The red lead 
connects to the positive battery terminal and the black lead connects to the 
negative terminal. 

Reversal of polarity of external battery will damage the 
PS100 or CH100. 

WARNING 

Содержание CH100

Страница 1: ...and CH100 Power Supply and Charging Regulators A100 Null Modem Adapter and A105 Additional 12 V Terminals Adapter Revision 4 09 C o p y r i g h t 2 0 0 0 2 0 0 9 C a m p b e l l S c i e n t i f i c I...

Страница 2: ...US and International customers residing in countries served by Campbell Scientific Inc directly Affiliate companies handle repairs for customers within their territories Please visit www campbellsci...

Страница 3: ...Use the Adobe Acrobat bookmarks tab for links to specific sections 1 General Description 1 2 Specifications 1 3 Wiring 2 4 A100 Null Modem Adapter 4 5 A105 12V Terminal Expansion Adapter 5 Figures 1 W...

Страница 4: ......

Страница 5: ...tific peripherals that would normally be connected to a datalogger These peripherals are typically modems linking different communications technologies e g telephone to radio The A105 Additional 12 V...

Страница 6: ...RMS Protection automatic reset 85 C thermal reset breaker UL Approval UL 1950 AC Transformer CSI Model No 14014 Input Voltage 90 264 VAC 47 63 Hz Output Voltage 18 VDC Output Current max 1 3 Amps UL A...

Страница 7: ...harged A battery must be attached for the charger to function correctly as a power supply CAUTION The leads from the transformer or solar panel are connected to the CHG terminals Polarity does not mat...

Страница 8: ...tic 4 A100 Null Modem Adapter The A100 has two 9 pin CS I O ports with a null modem between them The ports are used to connect two 9 pin devices that would normally be connected to the CS I O port on...

Страница 9: ...12 V 5 V 1 85 A Thermal Fuse FIGURE 3 Null Modem Connections 5 A105 12V Terminal Expansion Adapter The A105 adapter adds four 12 V terminals and four ground terminals to a CH100 or PS100 see Figure 4...

Страница 10: ...PS100 and CH100 Power Supply and Charging Regulators 6...

Страница 11: ......

Страница 12: ...a Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller Santo Doming...

Отзывы: