Section 4. Calculating Fluxes Using SPLIT
4-3
TABLE 4.2-1. Input Values for Flux Calculations
VARIB. VALUE UNITS
DESCRIPTION
CP
1.01
kJ/(kg K)
Specific heat of air
CW
4190.0
J/(kg K)
Specific heat of water
CS* 840.0
J/(kg
K) Specific heat of dry soil
(estimate)
EW**
2450.0
kJ/kg
Latent heat of vaporization at 20°C
P*
87.18
kPa
Atmospheric pressure, measure or
calculate for elevation
T** 1200
s
Output
interval
D**
0.08
m
Depth to flux plates
BD* 1200 kg/m
3
Soil bulk density,
must be
measured for site
W
vol-H2O/bulk
vol-soil
Soil water content, volume basis,
measured by the CS615
F
W/m
2
Soil heat flux measured at 8 cm.
S
W/m
2
Heat stored, calculated from soil
heat capacity and measured change
in temperature
G
W/m
2
Soil heat flux at surface (F+S)
RN
W/m
2
Net radiation, measured
BR
— Bowen
ratio
LE
W/m
2
Latent heat flux
H
W/m
2
Sensible heat Flux
0.622
Molecular weight of
water/molecular weight of air.
* These values are for a particular site. Correct values must be entered for the
site under study.
** These values may need to change if the program or installation is changed.
Содержание Bowen Ratio Instrumentation
Страница 10: ...Section 1 System Overview 1 6 This is a blank page ...
Страница 20: ...Section 2 Station Installation 2 10 This is a blank page ...
Страница 26: ...Section 3 Sample CR23X Program 3 6 This is a blank page ...
Страница 30: ...Section 4 Calculating Fluxes Using SPLIT 4 4 This is a blank page ...
Страница 34: ...This is a blank page ...
Страница 35: ...This is a blank page ...