Section 2. SimplePB.DLL Reference
Example of data returned by function call
"2004-04-16 14:18:03",1 (Time stamp, Record number)
1,OSversion,v03A
(Field number, Field name, Field value)
2,OSDate,06-Jan-04
3,ProgName,BATT.CR2
4,ProgSig,54451
5,CalOffset,2.625
6,PakBusAddress,1
7,RfInstalled,424
8,RfNetAddr,0
9,RfAddress,0
10,RfHopSeq,0
11,RfPwrMode,RF1_Sec
12,Rf_ForceOn,0
13,RfSignalLevel,0
14,RfRxPakBusCnt,0
15,VarOutOfBounds,0
16,SkipScan,0
17,TrapCode,0
18,WatchDogCnt,0
19,ResetTables,0
20,BattVoltage,12.3943
2.10 GetDataHeader()
Query the datalogger for only the header information from one of its tables.
Syntax
GetData(pakbus_address, device_type, table_no, return_data, return_data_len)
Parameters
pakbus_address: Integer – The PakBus address of the datalogger.
device_type: Integer – The type of datalogger:
•
1=CR200
•
2=CR10XPB, CR23XPB, CR510PB
•
3=CR1000
•
4=CR3000
•
5=CR800, CR850
table_no: Integer – The number of the table from which to collect data.
return_data: Char – The location in memory where the data returned from the
datalogger exists.