4.1.3 CR10X Example Program
;{CR10X}
*Table 1 Program
01: 1.0000 Execution
Interval
(seconds)
1: Pulse (P3)
1: 1
Reps
2: 1
Pulse
Channel
1
3: 2
Switch Closure, All Counts
4: 3
Loc [ Rain_mm ]
5: 0.2
Multiplier
6: 0
Offset
2: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 60
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
3: Set Active Storage Area (P80)
1: 1
Final
Storage
Area
1
2: 101
Array
ID
4: Real Time (P77)
1: 1220
Year,Day,Hour/Minute
(midnight
=
2400)
5: Totalize (P72)
1: 1
Reps
2: 3
Loc [ Rain_mm ]
*Table 2 Program
01: 0
Execution
Interval
(seconds)
*Table 3 Subroutines
End Program