![Campbell 237 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/campbell/237/237_product-manual_3761195011.webp)
237 Leaf Wetness Sensor
5
receives minimal direct sunlight at mid-day during the growing season.
Gillespie and Kidd favo
u
r a 60 degree tilt on a north facing sensor such
that water runs away from the cable connection to minimize puddling on
shows a simple-to-construct mounting
bracket.
FIGURE 7-1. Example 237 Field Installation
7.3 Wiring to Datalogger
is a circuit schematic of the 237. TABLE
Campbell Scientific dataloggers.
FIGURE 7-2. 237 Sensor Schematic
TABLE 7-1. Wire Colo
u
r, Function, and Datalogger Connection
Wire
Colo
u
r Wire Function
Datalogger Connection Terminal
Black
Voltage-
excitation input
U
configured for voltage excitation
1
,
VX
or
EX
(voltage excitation input)
Red
Analog
ue
voltage output
U
configured for single-ended analog
ue
input
1
,
SE
(single-ended, analog
ue
-voltage
input)
Purple
Bridge resistor
lead
⏚
(analog
ue
ground)
Clear
EMF shield
⏚
(analog
ue
ground)
1
U
channels are automatically configured by the measurement instruction.
⏚