MODEL 105T THERMOCOUPLE PROBE
4
;Knowing the wiring panel temperature, we now measure the 105T voltage and use the type T
;equation to calculate the 105T temperature. A multiplier of 1 and offset of 0 yield the
;temperature in °C in input location 2 (TC_Temp).
2: Thermocouple Temp (DIFF) (P14)
1:
1
Reps
2:
21
10 mV, 60 Hz Reject, Slow Range
3:
1
DIFF Channel
4:
1
Type T (Copper-Constantan)
5:
1
Ref Temp (Deg. C) Loc [ Ref_Temp ]
6:
2
Loc [ TC_Temp ]
7:
1.0
Mult
8:
0.0
Offset