6

Air leaking at trigger valve 

Air leaking between hous-
ing and nose

Air leaking between hous-
ing and cap

Nailer skips driving nail

Nailer runs slow or has loss
of power

Nails are jammed in nailer

Air leaking at trigger valve
stem

O-Rings in trigger valve housing are
damaged

Loose screws in housing

Damaged O-Rings

Damage to bumper

Loose screws

Damaged gasket

Worn bumper

Dirt in nose piece

Dirt or damage prevent nails or pusher
from moving freely in magazine

Damaged pusher spring

Inadequate air flow to nailer

Worn O-Ring on piston or lack of
lubrication

Damaged O-Ring on trigger valve

Air leaks

Cap gasket leaking

Nailer not lubricated sufficiently

Broken spring in cylinder  cap

Exhaust port in cap is blocked

Guide on driver is worn

Nails are not correct size

Nails are bent

Magazine or nose screws are loose

Driver is damaged

O-Rings or seals are damaged

O-Rings must be replaced & operation of work
contact element must be checked

Screws need to be tightened

O-Rings must be replaced

Bumper needs to be replaced

Screws need to be tightened

Gasket needs to be replaced

Bumper needs to be replaced

Drive channel needs to be cleaned

Magazine needs to be cleaned

Spring needs to be replaced

Fitting, hose or compressor needs to be checked

O-Rings need to be replaced. Lubricate.

O-Rings need to be replaced

Screws and fittings need to be tightened

Gasket needs to be replaced

Nailer needs to be lubricated

Spring needs to be replaced

Damaged internal parts need to be replaced

Guide needs to be replaced

Nails recommended for nailer must be use

Replace with undamaged nails

Screws need to be tightened

Driver needs to be replaced

O-Rings or seals need to be replaced

Troubleshooting Guide

Stop using nailer immediately if any of the following problems occur. Serious 
personal injury could result. Any repairs or replacements must be done by a

Qualified Service Person or Authorized Service Center.

Problem

Cause

Solution

Содержание NB0050

Страница 1: ...is tribute this instruction manual to all users The employer must also ensure all users read understand and follow the instructions as described in the manual safety warnings labels etc Danger indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Do not use any type of flammable gases or oxygen as a power source for the nailer Use filtered lubricat...

Страница 2: ...r parts Do not use the nailer if any shields or guards are removed or altered Do not use the nailer as a hammer Serious personal injury may occur Avoid long extended periods of work with the nailer The nailer can harm the user s hands or arm Stop using the nailer if pain occurs Always check the work con tact element WCE trip mechanism of the nailer A nail could acci dentally be dri ven if the trig...

Страница 3: ...ailer prop erly will dramatically shorten the life of the nailer and void your warranty 1 Disconnect the air supply from the nailer to add lubricant 2 Turn the nailer so the air inlet is facing up and put 4 to 5 drops of 30 W non detergent oil into air inlet Do not use deter gent oil or oil additives Run the nail er briefly after adding oil and wipe off excessive oil at the exhaust RECOMMENDED HOO...

Страница 4: ...ntact element WCE against the work surface The nailer MUST cycle 8 Depress the work contact element WCE against the work surface Pull the trigger The nailer MUST cycle LOADING UNLOADING THE NAILER 1 Always connect the tool to the air supply before loading fasteners 2 Press down on the latch Pull back on the magazine cover 3 Insert a stick of Campbell Hausfeld nails or equivalent See Fastener Secti...

Страница 5: ...sfeld finishing nails are available at local retail stores If you need help locating any item call customer service at 1 800 543 6400 Campbell Hausfeld nails meet or exceed Federal Specifications FF N 105B Shank Nails Per Nails Per Model Length Gauge Finish Head Collation Stick Box FB003060 1 1 4 16 Gauge Galvanized Brad Adhesive 50 2500 FB004060 1 1 2 16 Gauge Galvanized Brad Adhesive 50 2500 FB0...

Страница 6: ...s or seals are damaged O Rings must be replaced operation of work contact element must be checked Screws need to be tightened O Rings must be replaced Bumper needs to be replaced Screws need to be tightened Gasket needs to be replaced Bumper needs to be replaced Drive channel needs to be cleaned Magazine needs to be cleaned Spring needs to be replaced Fitting hose or compressor needs to be checked...

Страница 7: ...ident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is void D Normal adjustments which are explained in the owner s manual s provided with the product E Items or service that are normally required to maintain the product i e o rin...

Страница 8: ...Operating Instructions NB0050 Notes 8 ...