background image

properly. Do not use a compressed
air source capable of more than 200
PSI. The nailer could explode and
cause death or serious personal
injury.

Never use gasoline or
other flammable liq-
uids to clean the nail-
er. Never use the nail-
er in the presence  of
flammable liquids or
gases. Vapors could ignite by a spark
and cause an explosion which will
result in death or serious personal
injury.

Always place
yourself in a
firmly balanced
position when
using or han-
dling the
nailer.

Do not modify
or disable the
Work Contact
Element (WCE)
in a depressed
position or tape
or modify the
trigger in a pulled position. Death or
serious personal injury will occur.

Never keep the
trigger pulled
when carrying
or holding the
nailer. Make
sure not to pull
the trigger or
depress the
work contact element (WCE) trip
mechanism when connecting the
nailer to an air compressor. Death or
serious puncture wounds will occur
if the work contact element (WCE)
bumps something. 

Finishing Nailer

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury, death
and/or property damage! Retain instructions for future reference.

General Safety Information

This manual contains safety, operational
and maintenance information.

Read this manual and
understand all safety
warnings and instruc-
tions before operating
the nailer. Contact your
Campbell Hausfeld rep-
resentative if you have any questions.

The 

operator

of this nailer 

must

take

the necessary precautions to prevent
unsafe conditions outlined in this manu-
al from occurring. The operator is also
required to read and understand this
instruction manual and all safety warn-
ings, labels, etc.

Any 

employer

allowing the use of this

nailer in their field of work must dis-
tribute this instruction manual to all
users. The employer 

must

also ensure

all users read, understand and follow
the instructions as described in the
manual, safety warnings, labels, etc.  

Danger indicates 
an imminently

hazardous situation which, if not
avoided, WILL result in death or serious
injury.

Do not use any type
of flammable gases
or oxygen as a power
source for the nailer.
Use filtered, lubricat-
ed, regulated com-
pressed air only. Use
of a compressed gas instead of 
compressed air may cause the nailer
to explode and cause death or 
serious personal injury.

Do not exceed maxi-
mum operating pres-
sure of the nailer
(110 PSI). The nailer
will not function

Operating Instructions

Model NB0050

IN247201AV 1/97

Description

This nailer is designed for trimwork, interior molding, baseboards, paneling and
cabinet assembly and installation. Features include: convenient side loading maga-
zine which holds up to 100 nails, no-mar tip, adjustable exhaust, single cycle trig-
ger and quick clear nose.

Warning indicates
a potentially haz-

ardous situation which, if not avoided,
COULD result in death or serious
injury.

Disconnect the
nailer from air
supply before
adjusting, clear-
ing jams, servic-
ing, relocating
and during non-
operation. Remember it is possible
for the nailer to eject a fastener
after servicing the tool. ALWAYS
reconnect the air lines before load-
ing any fasteners. Death or serious
personal injury could result.

Protect your eyes and
ears. Wear Z87 safety
glasses, with side
shields. Wear hearing
protection. Employers
and users are respon-
sible for ensuring the
user or anyone near
the nailer wears this
safety protection.
Serious eye injury or
permanent hearing
loss could result. 

Do not use a
check valve or
any other fit-
ting which
allows air to
remain in the
nailer. Serious
personal injury
could occur.

MANUAL

CAMPBELL

HAUSFELD

Model NB0050

CAMPBELL

PROFESSIONAL

HAUSFELD

110 PSI

O

CO

2

Campbell Hausfeld Nailers meet or exceed Industries’ Standards as set forth by the American
National Standard/International Staple, Nail and Tool Association in ANSI/ISANTA SNT-101-1993.
© 1996 Campbell Hausfeld

Содержание NB0050

Страница 1: ...is tribute this instruction manual to all users The employer must also ensure all users read understand and follow the instructions as described in the manual safety warnings labels etc Danger indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Do not use any type of flammable gases or oxygen as a power source for the nailer Use filtered lubricat...

Страница 2: ...r parts Do not use the nailer if any shields or guards are removed or altered Do not use the nailer as a hammer Serious personal injury may occur Avoid long extended periods of work with the nailer The nailer can harm the user s hands or arm Stop using the nailer if pain occurs Always check the work con tact element WCE trip mechanism of the nailer A nail could acci dentally be dri ven if the trig...

Страница 3: ...ailer prop erly will dramatically shorten the life of the nailer and void your warranty 1 Disconnect the air supply from the nailer to add lubricant 2 Turn the nailer so the air inlet is facing up and put 4 to 5 drops of 30 W non detergent oil into air inlet Do not use deter gent oil or oil additives Run the nail er briefly after adding oil and wipe off excessive oil at the exhaust RECOMMENDED HOO...

Страница 4: ...ntact element WCE against the work surface The nailer MUST cycle 8 Depress the work contact element WCE against the work surface Pull the trigger The nailer MUST cycle LOADING UNLOADING THE NAILER 1 Always connect the tool to the air supply before loading fasteners 2 Press down on the latch Pull back on the magazine cover 3 Insert a stick of Campbell Hausfeld nails or equivalent See Fastener Secti...

Страница 5: ...sfeld finishing nails are available at local retail stores If you need help locating any item call customer service at 1 800 543 6400 Campbell Hausfeld nails meet or exceed Federal Specifications FF N 105B Shank Nails Per Nails Per Model Length Gauge Finish Head Collation Stick Box FB003060 1 1 4 16 Gauge Galvanized Brad Adhesive 50 2500 FB004060 1 1 2 16 Gauge Galvanized Brad Adhesive 50 2500 FB0...

Страница 6: ...s or seals are damaged O Rings must be replaced operation of work contact element must be checked Screws need to be tightened O Rings must be replaced Bumper needs to be replaced Screws need to be tightened Gasket needs to be replaced Bumper needs to be replaced Drive channel needs to be cleaned Magazine needs to be cleaned Spring needs to be replaced Fitting hose or compressor needs to be checked...

Страница 7: ...ident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is void D Normal adjustments which are explained in the owner s manual s provided with the product E Items or service that are normally required to maintain the product i e o rin...

Страница 8: ...Operating Instructions NB0050 Notes 8 ...

Отзывы: