background image

4

Maintenance

Disconnect power source
then release all pressure
from the system before
attempting to install, service, relocate
or perform any maintenance. Service
should be performed by an authorized
service representative.

The compressor should be checked
often for any visible problems and the
following maintenance procedures
should be performed each time the
compressor is used.

ASME SAFETY VALVE

Do not remove or
attempt to adjust

the safety valve!

Check the safety valve by performing
the following steps: 
1. Plug the compressor in and run until

shut off pressure is reached (see
Operating Procedure). 

2. Wearing safety glasses, pull the ring

on the safety valve to release
pressure from compressor tank. Use
your other hand to deflect fast-
moving air from being directed
toward your face.

3. The safety valve should close

automatically at approximately 40-50
psi. If the safety valve does not allow
air to be released when you pull on
the ring, or if it does not close
automatically, it MUST be replaced. 

DRAIN TANK

With compressor shut off and pressure
released, drain moisture from tank by
opening drain valve underneath tank.

CLEANING

Turn power OFF and clean dust and dirt
from pump cover, tank, and air lines.

IMPORTANT:

Unit should be located as

far from spraying area as hose will
allow to prevent over-spray from
clogging air filter.

LUBRICATION

This is an oilless type compressor
requiring no lubrication.

THERMAL OVERLOAD PROTECTOR

This com-pressor is
equipped with an

automatic reset thermal overload
protector which will shut off motor if it
becomes overheated.

If thermal overload protector shuts
motor OFF frequently look for the
following causes:

1. Low voltage

2. Lack of proper ventilation

If the thermal
overload protector is

actuated, the motor must be allowed to
cool down before start-up is possible. 

END OF OPERATION/STORAGE

1. Turn ON / OFF switch to the OFF

position.

2. Unplug power cord from wall outlet

and wrap around handle area to
prevent damage when not in use.

3. Wearing safety glasses drain tank of

air by pulling the ring on the safety
valve. Use other hand to deflect fast
moving air from being directed
toward your face.

4. Drain tank of condensation by

opening drain valve on bottom of
tank. Tank pressure should be below
10 psi when draining tank.  

5. Air hose should be disconnected

from compressor and hung open
ends down to allow any moisture to
drain.

6. Compressor and hose should be

stored in a cool, dry place.

Figure 5

MOISTURE IN COMPRESSED AIR

Moisture in compressed air will form into droplets as it comes from an air
compressor pump. When humidity is high or when a compressor is in continuous
use for an extended period of time, this moisture will collect in the tank. When
using a paint spray or sandblast gun, this water will be carried from the tank
through the hose, and out of the gun as droplets mixed with the spray material.

IMPORTANT: 

This condensation will cause water spots in a paint job, especially

when spraying other than water based paints. If sandblasting, it will cause the
sand to cake and clog the gun, rendering it ineffective. A filter in the air line
(MP3105), located as near to the gun as possible, will help eliminate this moisture.

Oilless Compressors

Figure 6

Содержание FP209699

Страница 1: ...tentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate inju...

Страница 2: ...o prevent health and fire hazards 18 Do not direct paint or other sprayed material at the compressor Locate compressor as far away from the spraying area as possible to minimize overspray accumulation...

Страница 3: ...nside motor Designed to keep the motor from overheating The motor has an auto reset protector To reset once the motor has cooled turn the switch to the OFF position then to the ON position This compre...

Страница 4: ...ad protector which will shut off motor if it becomes overheated If thermal overload protector shuts motor OFF frequently look for the following causes 1 Low voltage 2 Lack of proper ventilation If the...

Страница 5: ...5 Notes FP209501 FP209598 FP209599 FP209601 FP209699...

Страница 6: ...where temperature will not exceed 100 F 5 Check all electrical connections 6 Replace ON OFF switch 7 Replace pressure switch 8 Replace pump motor assembly 1 Move compressor to a clean well ventilated...

Страница 7: ...ic base 1 25 Pressure switch tube kit FP209535AV 1 26 Cap see part 10 1 27 Spring see part 10 1 28 Tank 1 29 Screw 2 30 Washer 2 31 Screw 4 32 Nut 4 33 Screw 4 34 Wire Clip FP202823AV 1 35 Screw 1 36...

Страница 8: ...E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component damaged in shipment or a...

Страница 9: ...rrer tout raccord boulon etc avant de mettre ce produit en service En cas de dommage ou de parties manquantes S V P composer le 1 800 543 6400 pour demander conseil Pri re d avoir le num ro de s rie n...

Страница 10: ...vante peut agiter la poussi re et le d bris qui peut tre dangereux L cher l air lentement en purgeant l humidit ou pendant la d pressurisation du syst me du compresseur 14 Utilisation d int rieur seul...

Страница 11: ...r gulateur sert r gler la pression d air la sortie du tuyau Le bouton du r gulateur se tourne dans le sens horaire droite pour augmenter la pression d air la sortie Le bouton du r gulateur se tourne d...

Страница 12: ...doit tre r alis seulement par un repr sentant de service autoris Inspecter le compresseur souvant et suivre les proc d s d entretien suivants pendant chaque utilisation du compresseur SOUPAPE DE S RE...

Страница 13: ...OFF ARR T 2 D brancher le cordon d alimentation de la prise et l enrouler autour du manche pour viter de l endommager pendant l entreposage 3 En portant des lunettes de s curit vidanger l air du r ser...

Страница 14: ...pas 38 C 100 F 5 V rifier toutes les connexions lectriques 6 Remplacer l interrupteur ON OFF 7 Remplacer le pressostat 8 Remplacer le montage de pompe moteur 1 D placer le compresseur dans un endroit...

Страница 15: ...usse de pressostat FP209538AV 1 10 Soupape de retenue Inclut 26 et 27 FP209532AV 1 11 Vis M4x0 7x6 1 12 Vis M6x1 0x10 4 13 Robinet de purge D 1403 1 14 Pieds en caoutchouc R servoir FP209522AV 4 15 Fi...

Страница 16: ...ints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un m...

Страница 17: ...ltos antes de poner la unidad en servicio En el caso de que haya da o o partes que faltan haga el favor de llamar al 1 800 543 8622 para obtener ayuda Tenga a mano el n mero de serie el n mero del mod...

Страница 18: ...e inspeccionar peri dicamente para detectar condiciones de peligro como la formaci n de xido y corrosi n 13 La circulaci n r pida de aire podr a levantar polvo y desperdicios da inos Siempre libere el...

Страница 19: ...expulsada por la manguera Al girar la perilla del regulador en sentido horario hacia la derecha la presi n de aire a la salida aumenta Al girar la perilla en sentido antihorario hacia la izquierda la...

Страница 20: ...or un representante de servicio autorizado Este compresor se debe chequear con frecuencia para ver si tiene alg n tipo de problemas y le debe dar el siguiente mantenimiento antes de cada uso VALVULA D...

Страница 21: ...enchufe el cord n del tomacorrientes de pared y envu lvalo alrededor del mango para prevenir da os cuando no se use 3 Con las gafas de seguridad puestas descargue el aire del tanque halando el anillo...

Страница 22: ...tura no exceda los 100 F 5 Verifique todas las conexiones el ctricas 6 Reemplace el interruptor ON OFF 7 Cambie el interruptor de presi n 8 Reemplace el ensamble de la bomba motor 1 Mueva el compresor...

Страница 23: ...de interruptor de presi n FP209538AV 1 10 Valvula de chequeo incluye 26 y 27 FP209532AV 1 11 Tornillo M4x0 7x6 1 12 Tornillo M6x1 0x10 4 13 V lvula de drenaje D 1403 1 14 Patas de caucho Tanque FP2095...

Страница 24: ...o cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en las instr...

Отзывы: