Camlogic SMD 20/P Скачать руководство пользователя страница 1

-

-
-
-

-
-

-

-

00919  99.09  -  Rev. 00

Fig.1

Fig.3

Fig.2

-

Max.  intervention  distance 10 mm.

Installation  and  Maintenance  Rules  for:

STANDARD  FEATURES

INSTALLATION

Inductive  motion  detector  SMD 20/P

The   inductive   motion   detector  

SMD  20/P

   is   made   in   compliance   with   the   regulations   in   force   in   the   European   Union

and  specifically  with:

Die-cast  aluminium  casing  UNI 5076.  IP65  protection.  

SMD20

,  in  regards  to  the  classification  of  zones  according  to  the  danger

Installation  with  carrier  bracket.
Motion  detection  by  induction  sensor  without  mechanical  coupling.
Electrical  construction  in  compliance  with  EC  Directives  73/23,  93/68  on  low-voltage

Test   Report   No.  04-09-97-C87   issued   by   Laboratorio   Universitario   di   Compatibilità
Elettromagnetica  " Leopoldo  Nobili "  via  Paterlini  10,  Reggio  Emilia,  Italy.
Noise  level  measured  in  open  field:     zero
Envisaged  power  supplies:     110/220 V  50/60 Hz  -  24/48 V  50/60 Hz  -  24 V DC
Use  contact  capacity:              5 A  at  250 V AC

SAFETY  RULES

All  the  appropriate  safety  precautions  must  be  taken  when  electrically  operated  equipment  is  used,  in  order  to  reduce
the  risk  of  fire  outbreaks,  electric  shock  and  injuries  to  persons.

- Keep  the  work  zone  clean  and  orderly.  Accidents  are  more  likely  to  occur  in  untidy  areas  and  environments.
- Before  beginning  work,  make  sure  that  the  motion  detector  is  in  a  perfect  condition.  Damaged  or  broken  parts  must

be  repaired  or  replaced  by  competent  personnel  authorized  by  the  Manufacturer.

- All   verifications,   inspections,   cleaning   and   maintenance   operations,   part   changes   and   replacements   must   be   carried

out  with  the  motion  detector  disconnected  and  the  plug  removed  from  the  power  socket.

- It  is  absolutely  forbidden  for  children,  unauthorized  and/or  inexpert  persons  to  touch  or  use  the  motion  detector.
- Make   sure   that   the   electricity   system   complies   with   the   laws   in   force.   Make   sure   that   the   earthing   is   efficiently

connected   when   the   instrument   is   installed.   Check   to   be   sure   that   the   power   socket   is   suitable,   that   it   complies

- The  motion  detector  must  never  be  stopped  by  detaching  the  plug  from  the  power  socket.  Moreover,  never  use  the

cable  to  pull  the  plug  from  the  socket.

- Periodically   check   to   be   sure   that   the   cable   is   in   a   perfect   condition   and   replace   it   if   damage   is   discovered.   This

operation  must  only  be  carried  out  by  competent  and  authorized  persons.  Only  use  extensions  cables  of  the  permitted

- Do  not  allow  children  oe  unauthorized  persons  to  touch  the  cable  when  the  instrument  is  plugged  in.

Before   proceeding   with   the   installation   operations,

Operating  temperature:             from  -15  to  +70 °C
Field  of  use:                             30 - 6000  pulses/minute

visually   inspect  

SMD  20/P

   in   order   to   be   sure   that

it   has   not   been   damaged   during   transport   or
the   storage   period.   If   this   check   reveals   anything
irregular,   the   motion   detector   must   be   sent   to

CAMLOGIC  Snc

  to  be  restored  to  efficiency.

The   constructional   characteristics   of   the   unit   that
detections   the   motions   can   be   installed   so   that

the   cable   input   is   turned   at   90°   intervals,   allowing   the   power   cable   to   be   fixed
in   the   most   favourable   position   (  Fig.1  ).

Installation   can   be   done   in   two   ways:   by   radial   signal   reading   (  Fig.2  )   or   by
off-centre   in-line   reading   (  Fig.3  ).   Whatever   the   method   sensor   head   must   not   be
more  than  10 mm.  from  actuator  revolving  surface.  Sensor  axis  must  be  at  the  middle
line  of  actuator  side  surface  for  a  radial  read  out.  If  signal  reading  is  axial,  sensor  axis
must  coincide  with  insert  mid-point  as  show  in  the  " REFERENCE  FIGURES ".

CAMLOGIC

   inductive   motion   detectors   can   be

installed  in  any  position.

with  the  laws  in  force  and  that  it  has  a  build  in  automatic  protection  circuit-breaker.

type  and  marked.  Protect  the  cable  against  high  temperatures,  lubricants  and  sharp  edges.  Do  not  twist  or  knot  the  cable.

electrical  material,  EC  Directives  89/336,  92/31  on  electromagnetic  compatibility  with

ELECTRICAL  WIRING

The   conductors   forming   the   power   supply   and   signal   carrying   cable   must   have   an
adequate  cross-section  so  that  the  current  density,  in  each  conductor,  is  no  higher  than

90°

90°

90°

90°

R

S.n.c.  di  Pigozzi  A. Amos  &  C.

COSTRUZIONI  MECCANICHE  ELETTRICHE

Via  dell' Industria  12 - 12/A  -  42025  CAVRIAGO  -  RE  -  Italy
Tel. 0522942641 - 0522941172 - Fax  0522942643

www.camlogic.it

e-mail  [email protected]

0044

Serial Number :  00.48.0000

Production  Year  0000

Via  dell' Industria  12 - 42025  CAVRIAGO  RE - Italy

0044

II  2D  Ex  tD  A21  IP65  T87 °C

TÜV NORD CERT

GmbH

Directive  94/9/EG

Pr

o

ducti

o

n  Q u

al

it

y

As

sura

nce  certi

fie

d

REV  MONITOR

Do not open when energized

WARNING

Max. Imp/mn 6000 -15 °C < Tamb < +60 °C

TÜV  11  ATEX  386761

SMD20/P

V. 110/220  50/60 Hz

4 A/mm².  One  of  these  is  used  only  for  the  earthing of  the  motion  detector.

of  combustible  dust  explosion  (EC  Directive  94/9 EC),  can  be  used  in  zone  21  or  zone  22.