background image

3

M3
4.5 low

48

30 

±0.1

120°

7

26.1

Ø1/4˝  
(6.35 g6)

Ø

20 f7

Ø

40 f7

1

1

12

1.5

– 0.005
– 0.014

6

Ø2

Fig. 6. KINAX 2W2 with special drive shaft at front and at rear.
Front: dia. 1/4

ʺ

, length 12 mm [0.472

ʺ

]

. Rear: dia. 2 mm, length 6 mm [0.078

ʺ

0.236

ʺ

].

6. Mounting

Mechanical mounting

All versions of the transmitter can be mounted either directly or by means of 3 
mounting clips to the item being measured. Both methods of mounting and the 
relevant drilling and cut-out plans can be seen from Table:

Mounting versions

2

Drilling and cut-out diagrams

for mounting transmitters)

dir

ectly

M3
4.5 low

[0177]

900

12

24

36

0

600

Load max. [Ω] with
output 20 mA

Power supply [V]

30

10

with 3 clamps

65

±0.1

M4

120°

40

+ 0.025

+

0

[1.574]

[2.559]

Mounting/positioning

Three 

M3 

screws are needed for the 

“directly”

 mounted versions and three 

M4

 

screws for those 

“with clamps”

. The screws are not supplied, because the required 

length varies according to the thickness of the mounting surface.

When deciding where to install the transmitter (measuring 
location), take care that the 

“Ambient conditions”

 given in 

Section “5. Technical data” are 

not exceeded

.

Angular position transmitters of the KINAX 2W2 range do not require a mechani-
cal zero position mark (however, this is made if required by the customer). After 
mounting, the transmitter can be moved to any position and confi gured using the 
2W2 software. A power supply connection to the KINAX 2W2 is not required in 
order to use the 2W2 confi guration software (Fig. 7; AUX switch on the PK 610 in 
the ON position.

The angular position transmitter must only be programmed 
outside of the Ex areal!

Programming
connector

Interface

KINAX 2W2

PK 610

Ancillary cable

OFF

ON

OFF: Power supply
by measuring output
(Fig. 10)
ON: Power supply
provided by PC

Fig. 7. Connection diagram programming

If you programm the KINAX 2W2 with a connected power 
supply, then the switch on the interface PK610 must be im-
perative switched to OFF. If this is ignored, this can lead to the 
destruction of the device.

Positioning procedure for the KINAX 2W2

1.  Mount the angular position transmitter and mechanically connect it to the object 

to be measured. Connect the KINAX 2W2 to the programming device according 
to Fig. 7. Start the 2W2 confi guration software. If necessary, confi gure the device 
with the required measuring range data.

2.  Place the measuring device in a defi ned position (prefereably the zero position).
3. Select the 

“Adjustment” 

menu item under 

“SERVICE”

 in the confi guration 

software. In the 

“Mechanical position”

 window enter the current angle of 

the measuring device and then select 

“Adjust”.

 The measuring device is now 

confi gured for the defi ned angle.

7. Electrical connections

For connecting the external wires, the transmitter has 2 soldering pins at the back 
(Fig. 8) or a connecting print with screw terminals (Fig. 9). The soldering posts 
suffi ce Protection Class IP 00 acc. to IEC 60 529.

Programming
connector

Soldering plugs

Programming
connector

Cable-tie
clamp

Screw terminals

Fig. 8. Connection with soldering plugs

    

Fig. 9. Connection with screw terminals

Note that, …

…   the data required to carry out the prescribed measurement must 

correspond to those marked on the nameplate of the KINAX 2W2 
(Range, Output, Supply Voltage)!

…  the total loop resistance connected to the output (receiver plus 

leads) 

does not

 exceed the maximum permissible value R

ext.

! See 

“Measuring output”

 in Section “5. Technical data” for the maximum 

values of R

ext.

!

…  twisted cores must be use for the measured variable input and 

output leads and routed as far away as possible from power cables!

In all other respects, observe all local regulations when selecting the 
type of electrical cable and installing them!

In the case of 

“Intrinsically safe” 

explosion-proof versions 

[Ex ia] IIC, the supplementary information given on the EC-Type-
Examination Certifi cate, the EN 60 079-14 and also local regulations 
applicable to electrical installations in explosion hazard areas must 
be taken into account! 

Do not 

excessively heat 

the soldering posts!

Solder using a 

small

 pencil bit soldering iron!

H

R

ext

Soldering
plugs

+

H

R

ext

Cable-tie
clamp

Screw terminals

+

H = 

DC

 power supply H = 12 to 33 V resp. H = 12 to 

30

 V with 

Ex

 version

R

ext. 

= External resistance

 

Fig. 10. Connection diagrams for 2-wire connection.

8. Setting the beginning and end

Fine adjustment

T

he analog output can be fi nely adjusted using the 2W2 confi guration software. 

Select the menu item 

“Adjustment”

 under 

“SERVICE”

. In the 

“Analog output”

 

window, the zero position and the end value can now be adjusted.

Procedure:

1.  Put the transmitter into operation and connect the programming device according 

to Fig. 7 (AUX switch on the PK 610 in the OFF position).

2.  Place the measuring device in the zero position, i.e. in the position in which the 

KINAX 2W2 should output 4 mA. Adjust with the 

“ZERO”

 virtual knob until the 

output is correct.

Отзывы: