background image

D I S T R I B U T E D   V A L V E S

03/2011  /  IOM-NAV-BALL-S30 

5

Installation, Operation and Maintenance Manual

Scope

The NAVCO

®

 S30 3-piece ball valve is designed to satisfy a wide range of industrial and oilfield applications. It 

has a swing out body, allowing the internals to be serviced while inline. The S30 comes standard with an 
ISO 5211 mounting pad and stem, an adjustable, replaceable stem packing and is manufactured in carbon steel 
and stainless trims. Sizes are available from ½” to 2” full bore, with threaded or socket weld end connections. 
MOP is 2000psi for ½” through 1” and 1500psi 1-1/4” thru 2”.

Storage

After valves are assembled and tested, they are placed in the full open position, bores are greased and end 
protectors are installed. These measures will provide adequate protection for approximately six months. 
Extended indoor/outdoor storage requires periodic inspection and the addition of a corrosion inhibitor. 

If long term storage is required, the valve should be conditioned by following Cameron procedure X-150771-01 
and ensure adequate end connection covers are in place. Contact your Cameron representative for the 
extended storage guidelines. 

Valves should only be stored in the full open or full closed position to prevent seat distortion.

Installation

NAVCO S30 3-piece ball valves may be installed in any position with flow from either direction. However, for 
best service life there is a preferred vertical or horizontal position, to maximize sealing and minimize the 
accumulation of sediment.

In the vertical position it is preferred to have the upstream pressure from above so the weight of the ball will 
assist the pressure in sealing. With the run of the valve in a horizontal position, it is preferred to have the stem 
lying horizontal (i.e. toward the viewer), with pressure from the right. During operation, flow will act as a 
siphon and minimize retention of sediment. 

When handling or installing a valve, keep the valve in the full open position whenever possible to prevent 
damage to the ball seal area. Threaded-end valves are installed using two wrenches, one on the flats of the 
tailpiece adjacent to the pipe being installed, and the other on the adjacent pipe. 

For socket weld end, to prevent ball and seat damage due to excessive heat or weld slag, the following 
procedure is recommended for welding NAVCO

®

 S30 valves into a line:

1. 

Use solvent to clean grease or rust inhibitor from the ball and/or bore of the valve.

2.  

Electric welding equipment is preferred for all installations. However, if only oxygen/acetylene welding  

 

equipment is available, extreme caution should be taken regarding excess welding temperature.

3. 

Weld with ball in the Full Open position.

4.  

Make sure the temperature of body/seat area does not exceed 250F (Check with a Tempil stick).

Содержание NAVCO S30

Страница 1: ...DISTRIBUTED VALVES NAVCO S30 Three Piece Swing Out Ball Valve NAVCO Installation Operation and Maintenance Manual ...

Страница 2: ...DISTRIBUTED VALVES 2 03 2011 IOM NAV BALL S30 Installation Operation and Maintenance Manual ...

Страница 3: ... NAV BALL S30 3 Installation Operation and Maintenance Manual NAVCO S30 THREE PIECE SWING OUT BALL VALVE Bill of Materials 4 Scope 5 Storage 5 Installation 5 Operation 6 Routine Maintenance 7 Repair 7 Reassembly 8 TABLE OF CONTENTS ...

Страница 4: ...lation Operation and Maintenance Manual Bill of Materials Item Description 1 Body 2 Ball 3 Cap 4 Seat 5 Thrust Washer 6 Joint Gasket 7 Packing 8 Washer Item Description 9 Bolt 10 Packing Nut 11 Stem 12 Washer 13 Nut 14 Handle 15 Handle Cover 16 Body Seal ...

Страница 5: ...lves may be installed in any position with flow from either direction However for best service life there is a preferred vertical or horizontal position to maximize sealing and minimize the accumulation of sediment In the vertical position it is preferred to have the upstream pressure from above so the weight of the ball will assist the pressure in sealing With the run of the valve in a horizontal...

Страница 6: ...working pressure rating without consulting the factory 3 Seat Testing When testing the seats with the valve in the closed position do not exceed the valve s cold working pressure rating 4 Upon completion of testing purge all test fluids from the valve and return to the required operating position either fully open or fully closed Operation NAVCO S30 ball valves operate from fully open to fully clo...

Страница 7: ...ing or refurbishing a valve ensure that the valve and line has been fully de pressurized drained and where necessary purged of all toxic explosive flammable media Refer to Exploded Parts view on page 1 for part location Turn ball 02 to open position and remove handle nut 13 washer 12 handle 14 packing nut 10 packing 07 and stop screw Loosen one bolt per side in line with each other and remove the ...

Страница 8: ...he ball slot with the stem drive tang The ball should be in the closed position Rotate ball 02 to the open position Install joint gaskets 06 for each side of the body 01 Apply grease to the face of each seat 06 and simultaneously press seats into i d of the body bore and joint gaskets 06 until contact is made with the ball Carefully avoiding damage to the seats and seals during assembly swing valv...

Страница 9: ...l Install handle 14 handle washer 12 and handle nut 13 Install stop screw in the correct threaded hole to insure the valve operates from open to close by pulling the handle towards you Open and close valve several times to check for smooth operation Verify the sealing integrity of the valve ...

Страница 10: ...02 DISTRIBUTED VALVES VALVES MEASUREMENT 3250 Briarpark Drive Suite 300 Houston TX 77042 USA Toll 800 323 9160 For the most current contact and location information go to www c a m com 03 2011 IOM NAV BALL S30 Installation Operation and Maintenance Manual ...

Отзывы: