December 2006

 

CMC-250 Circulating System

 

Operation 

 
1.

 

After a sample is received into the receptacle, turn the pump motor ON for 

at least

 5  

minutes

 to circulate the fluid (see note below). 

 

 

A 5-gal system requires a minimum circulation time of 5 minutes or until the volume 
in the receptacle is circulated five times. 

 

 

A 10-gal system requires a minimum circulation time of 10 minutes of circulation or 
until the volume has been circulated five times.

 

NOTE:  The pump is rated at approximately 5.0 gpm  at 0 psig backpressure and a fluid 
viscosity of 100 SUS (21.6 CTS) at 60

°

F (16

°

C). 

 
For most light to medium-weight crude oils ranging up to API 24 with a kinematics viscosity 
less than 160 CTS at 60

°

F (16

°

C), 5 minutes of circulation time should adequately mix the tank 

volume. 
 
For most crude oils heavier than API 24 with a kinematics viscosity greater than 160 CTS and 
temperatures below 60

°

F (16

°

C), consider allowing additional circulation time to ensure the 

tank volume is thoroughly mixed. 

2.

 

While the circulating pump is ON, open the sample draw-off valve (item 8), allowing the 
sample to flow directly into laboratory glassware. Close the sample draw-off valve (item 
8) and cap the laboratory sample transport receptacle immediately.

 

3.

 

To drain the (tank) receptacle, perform the following steps: 

a.

 

Turn the circulating pump ON. 

b.

 

Close the return valve (item 13A). 

c.

 

Open the drain valve (item 13B) and pump isolation valve (item 13 C), and allow the 

receptacle to drain. 

d.

 

When the receptacle is empty, close the pump isolation valve (item 13 C) and open 

the return valve (item 13A) to drain the re-circulating tubing (item 9). 

e.

 

Turn the pump motor off, and close all valves. 

4.

 

To remove the cover on the receptacle, perform the following steps: 

a.

 

Open the sample draw-off valve (item 8) to relieve the pressure from the receptacle. 

b.

 

After the pressure is relieved, turn the plastic knob counter-clockwise until threads in 

the knob disengage from the stud in the top of the lid.  

5.

 

Thoroughly clean the receptacle after every sampling batch to prevent cross-
contamination of sampled fluids. 

Содержание CLIF MOCK CMC-250

Страница 1: ...Manual No 99104500138 Rev C CLIF MOCK CMC 250 Circulating System User Manual ...

Страница 2: ......

Страница 3: ... confidential and proprietary property of Cameron Any reproduction or use of these instructions drawings or photographs without the express written permission of an officer of Cameron is forbidden All Rights Reserved Printed in the United States of America Manual No 99104500138 Rev C December 2006 ...

Страница 4: ......

Страница 5: ...CMC 250 Circulating System 1 December 2006 Table of Contents Description 1 Installation 3 Startup Procedures 3 Operation 4 CMC 250 Circulating System Bill of Materials 5 ...

Страница 6: ...December 2006 2 CMC 250 Circulating System ...

Страница 7: ... a sump or back into the pipeline NOTE Pipeline pressure must be less than 100 psi when returning collected sample back into the pipeline 4 Install the ON OFF Switch supplied by customer near the CMC 250 Circulating System 5 Check all electrical connections All field wiring must conform to the National Electric Code NFPA 70 Local wiring ordinances may also apply This equipment is for use in non cl...

Страница 8: ...tion time to ensure the tank volume is thoroughly mixed 2 While the circulating pump is ON open the sample draw off valve item 8 allowing the sample to flow directly into laboratory glassware Close the sample draw off valve item 8 and cap the laboratory sample transport receptacle immediately 3 To drain the tank receptacle perform the following steps a Turn the circulating pump ON b Close the retu...

Страница 9: ...psi 5 1 50142381037 0 60 psi Liquid Filled Pressure Gauge 6 1 50142303543 Vacuum Relief Valve 1 psi 7 1 50142302882 Inlet Connection in Tbg SS 8 1 50142208006 Valve Sample Draw Off 9 1 50142302204 Tubing in SS 10 1 50142302204 Spray Bar Internal SS 11 1 50142304100 Static Mixer in SS 12 1 50142310046 Shut Off High Level Assy 13 3 50142303651 Ball Valve in SS 14 1 50142304008 in NPT Gear Pump 15 4 ...

Страница 10: ...December 2006 6 CMC 250 Circulating System ...

Страница 11: ...ty and Buyer s exclusive remedy in any case of action whether in contract tort breach of warranty or otherwise arising out of the sale or use of any products software supplies or materials is expressly limited to the replacement of such products software supplies or materials on their return to Seller or at Seller s option to the allowance to the customer of credit for the cost of such items In no...

Страница 12: ......

Отзывы: