CLIF MOCK 

 

CMC-250  

 

Circulating System 

 

 

User Manual 

Содержание CLIF MOCK CMC-250

Страница 1: ...Manual No 99104500138 Rev C CLIF MOCK CMC 250 Circulating System User Manual ...

Страница 2: ......

Страница 3: ... confidential and proprietary property of Cameron Any reproduction or use of these instructions drawings or photographs without the express written permission of an officer of Cameron is forbidden All Rights Reserved Printed in the United States of America Manual No 99104500138 Rev C December 2006 ...

Страница 4: ......

Страница 5: ...CMC 250 Circulating System 1 December 2006 Table of Contents Description 1 Installation 3 Startup Procedures 3 Operation 4 CMC 250 Circulating System Bill of Materials 5 ...

Страница 6: ...December 2006 2 CMC 250 Circulating System ...

Страница 7: ... a sump or back into the pipeline NOTE Pipeline pressure must be less than 100 psi when returning collected sample back into the pipeline 4 Install the ON OFF Switch supplied by customer near the CMC 250 Circulating System 5 Check all electrical connections All field wiring must conform to the National Electric Code NFPA 70 Local wiring ordinances may also apply This equipment is for use in non cl...

Страница 8: ...tion time to ensure the tank volume is thoroughly mixed 2 While the circulating pump is ON open the sample draw off valve item 8 allowing the sample to flow directly into laboratory glassware Close the sample draw off valve item 8 and cap the laboratory sample transport receptacle immediately 3 To drain the tank receptacle perform the following steps a Turn the circulating pump ON b Close the retu...

Страница 9: ...psi 5 1 50142381037 0 60 psi Liquid Filled Pressure Gauge 6 1 50142303543 Vacuum Relief Valve 1 psi 7 1 50142302882 Inlet Connection in Tbg SS 8 1 50142208006 Valve Sample Draw Off 9 1 50142302204 Tubing in SS 10 1 50142302204 Spray Bar Internal SS 11 1 50142304100 Static Mixer in SS 12 1 50142310046 Shut Off High Level Assy 13 3 50142303651 Ball Valve in SS 14 1 50142304008 in NPT Gear Pump 15 4 ...

Страница 10: ...December 2006 6 CMC 250 Circulating System ...

Страница 11: ...ty and Buyer s exclusive remedy in any case of action whether in contract tort breach of warranty or otherwise arising out of the sale or use of any products software supplies or materials is expressly limited to the replacement of such products software supplies or materials on their return to Seller or at Seller s option to the allowance to the customer of credit for the cost of such items In no...